Application Unit (IAU) / Control Unit (ICU) storage control system and power plant controller
Country: Germany · Model: IAU / ICU
The Application Unit (IAU) and Control Unit (ICU) pair runs storage plants and includes a power plant controller certified to VDE-AR-N 4110 and 4120. The IAU is the central top-level controller, and the ICU sits between it and the inverters with their IBU battery units. Through it the storage takes commands from the grid operator, traders, PV and wind plants and external EMS.
- Power plant controller
- certified to VDE-AR-N 4110 and 4120
- Protocols
- Modbus TCP/IP, Modbus RTU, IEC 60870-5-101/104
- Meters
- up to 5
- Modes
- grid-parallel and grid-forming
Technical specifications
| Power plant controller | certified to VDE-AR-N 4110 and 4120 |
|---|---|
| Protocols | Modbus TCP/IP, Modbus RTU, IEC 60870-5-101/104 |
| Meters | up to 5 |
| Modes | grid-parallel and grid-forming |
| Functions | FCR (built-in precision frequency measurement), peak shaving, spot and balancing markets |
| Installation | indoor and outdoor |
| More from the manufacturer’s documentation | |
| Structure | 4 modules: interface, application, grid compliance, system functions |
| ABC architecture | IAU (overarching control) — ICU (control unit for IBUs and inverters) — IBU (battery unit); IDG data gateway |
| Scaling | Up to 16 ICUs per IAU (24 ICUs planned), up to 4 BESUs per ICU, up to 64 BESUs per IAU |
| System example | 4 BESUs of 8.1 MWh / 4.6 MVA each: 32.4 MWh / 18.4 MVA |
| ICU | Several IBUs and up to 4 inverters (DC strings); ModBUS interface to master BMS; power distribution between DC strings |
| IBU | 1 battery bank of up to 8 racks |
| ICU power backup and climate | UPS, air conditioning for operation in nearly all ambient temperatures |
| Safety functions | External fire alarm connection with battery shutdown, cascaded connection during black start, charge/discharge derating |
| Grid topology | Ring, line or star |
| Control functions | Ramping, clustering, power distribution between AC strings |
| Grid connection | Per for new and existing plants; usable as overarching or downstream power plant controller |
| Integration | Generation plants (PV, wind, hydro), multiple traders, grid operators, reading of existing power plant controllers |
| Applications | Grid connection expansion, power procurement optimization, atypical/intensive grid usage, exchange trading, multi-market, backup power / island grid |
| Customs codes (for reference) | |
| HS code | 9032.89 |
| UKTZED code (Ukraine) | 9032890000 |
| CN code (EU) | 90328900 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
The IAU is built from 4 modules covering interface, application, grid compliance and system functions. Data runs over Modbus TCP/IP, Modbus RTU and IEC 60870-5-101/104, and up to 5 meters connect to the controller. Under its control the storage runs grid-parallel or grid-forming, including island operation for backup power. Built-in precision frequency measurement serves frequency containment reserve (FCR), and other tasks are peak shaving, ramping and trading on spot and balancing markets. The ICU splits power between the DC strings of up to 4 inverters and talks to the master BMS over ModBUS, while a UPS backs up its own supply. An external fire alarm signal shuts the batteries down, and in black start they connect in cascade. The network runs as a ring, line or star, and units go indoors or outdoors.
How to choose
Size the control system by the BESU count. One ICU handles up to 4 BESUs and one IAU up to 16 ICUs (24 planned), so up to 64 BESUs per site. For example, 4 BESUs of 8.1 MWh / 4.6 MVA give 32.4 MWh and 18.4 MVA under one IAU. With the cabinet-type scalepac one IAU runs 4–16 blocks of 254 kWh, and with the 4,600 kVA scalecube i3 and scalecube i4 grid blocks it adds telecontrol over IEC 60870-5-101/104.
Request a price and lead time
Application Unit (IAU) / Control Unit (ICU) storage control system and power plant controller. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Which protocols does the IAU controller support?
It supports Modbus TCP/IP, Modbus RTU and IEC 60870-5-101/104.
Is the power plant controller certified to VDE-AR-N 4110?
Yes, the power plant controller is certified to VDE-AR-N 4110 and 4120.
How many meters can connect to the control system?
Up to 5 meters connect to the control system.
How many BESU blocks can one IAU control?
Up to 64 BESUs, 4 on each of 16 ICUs, and the IAU is planned to accept up to 24 ICUs.
Can an IAU be added to an existing plant?
Yes, connection covers new and existing plants, with the IAU as overarching or downstream power plant controller.