Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

CHARGE CONTROLLERS AND EMS

EMS — energy management system controller

The EMS brings PV plants, wind plants, storage, generators and charging stations of a microgrid or grid site under one control. The housing is 478.8×87×811.7 mm, weight about 28 kg, power supply 90–264 V AC.

Dimensions
478.8×87×811.7 mm
Weight
≈28 kg
Power supply
90–264 V AC
Communication
Ethernet

Technical specifications

Dimensions478.8×87×811.7 mm
Weight≈28 kg
Power supply90–264 V AC
CommunicationEthernet
EMCclass B
Operating temperature5…45 °C

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

This is a hardware and software complex that gathers all sources and consumers of a site into one dispatching system. Hot standby redundancy keeps control going if the main controller fails. There is integration with VPP and trading platforms, so the site can be connected to the electricity market. The 90–264 V AC supply is not tied to a local grid standard. Communication is over Ethernet. EMC class B means the device may be installed next to office and residential equipment. The operating temperature of 5…45 °C requires a climate-controlled room, so an outdoor cabinet without heating and ventilation is not used for it. The unit weighs about 28 kg.

How to choose

If the task comes down to battery monitoring, a BMS is enough, and the EMS is needed where several kinds of generation and loads meet on one bus. For a microgrid with transition between the grid and island there is the MCC, which switches in less than 10 ms. For a small site with cloud control, the ECC at 9–28 V DC, with dimensions of 108×137×36 mm, is suitable.

Request a price and lead time

EMS — energy management system controller. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which energy sources can the EMS combine?

PV plants, wind plants, storage, generators and charging stations at microgrid, commercial and grid sites.

Does the EMS have redundancy?

Yes, hot standby redundancy of the controller is provided. Integration with VPP and trading platforms is declared separately.

What voltage does the EMS run on?

The power input has a range of 90–264 V AC, so the controller works from grids of different standards.

What are the operating temperature and weight of the EMS?

Operating temperature is 5…45 °C, weight about 28 kg, dimensions 478.8×87×811.7 mm.

What EMC class does the EMS have?

Class B, meaning the device can be installed in office and residential premises.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.