EMS — energy management system controller
Country: · Model: EMS
The EMS brings PV plants, wind plants, storage, generators and charging stations of a microgrid or grid site under one control. The housing is 478.8×87×811.7 mm, weight about 28 kg, power supply 90–264 V AC.
- Dimensions
- 478.8×87×811.7 mm
- Weight
- ≈28 kg
- Power supply
- 90–264 V AC
- Communication
- Ethernet
Technical specifications
| Dimensions | 478.8×87×811.7 mm |
|---|---|
| Weight | ≈28 kg |
| Power supply | 90–264 V AC |
| Communication | Ethernet |
| EMC | class B |
| Operating temperature | 5…45 °C |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
This is a hardware and software complex that gathers all sources and consumers of a site into one dispatching system. Hot standby redundancy keeps control going if the main controller fails. There is integration with VPP and trading platforms, so the site can be connected to the electricity market. The 90–264 V AC supply is not tied to a local grid standard. Communication is over Ethernet. EMC class B means the device may be installed next to office and residential equipment. The operating temperature of 5…45 °C requires a climate-controlled room, so an outdoor cabinet without heating and ventilation is not used for it. The unit weighs about 28 kg.
How to choose
If the task comes down to battery monitoring, a BMS is enough, and the EMS is needed where several kinds of generation and loads meet on one bus. For a microgrid with transition between the grid and island there is the MCC, which switches in less than 10 ms. For a small site with cloud control, the ECC at 9–28 V DC, with dimensions of 108×137×36 mm, is suitable.
Request a price and lead time
EMS — energy management system controller. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Which energy sources can the EMS combine?
PV plants, wind plants, storage, generators and charging stations at microgrid, commercial and grid sites.
Does the EMS have redundancy?
Yes, hot standby redundancy of the controller is provided. Integration with VPP and trading platforms is declared separately.
What voltage does the EMS run on?
The power input has a range of 90–264 V AC, so the controller works from grids of different standards.
What are the operating temperature and weight of the EMS?
Operating temperature is 5…45 °C, weight about 28 kg, dimensions 478.8×87×811.7 mm.
What EMC class does the EMS have?
Class B, meaning the device can be installed in office and residential premises.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.