Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

CHARGE CONTROLLERS AND EMS

VarioString VS 70/120 — high-voltage MPPT charge controllers 48 V

VarioString high-voltage MPPT charge controllers at 70 and 120 A for 48 V batteries, with PV input up to 600 V, or 900 V on the VS 120. They suit sites where the array sits far from the battery room and long strings on thin cable pay off.

Models
VS 70, VS 120
Charge current
70 A (VS 70), 120 A (VS 120)
PV power
4200 W (VS 70), up to 7000 W (VS 120)
PV voltage (Voc)
600 V; VS 120 — 900 V with 2 inputs in series

Technical specifications

ModelsVS 70, VS 120
Charge current70 A (VS 70), 120 A (VS 120)
PV power4200 W (VS 70), up to 7000 W (VS 120)
PV voltage (Voc)600 V; VS 120 — 900 V with 2 inputs in series
Battery voltage48 V DC (38–68 V)
Efficiency> 98 %, MPPT > 99.8 %
Galvanic isolationyes
Protection ratingIP54 (VS 70), IP20 (VS 120)
Customs codes (for reference)
HS code8504.40
UKTZED code (Ukraine)8504405500
CN code (EU)85044060

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Galvanic isolation separates the PV input from the battery, so strings of several hundred volts are not tied to the 48 V bus or system ground. The VS 70 takes 4200 W and charges at 70 A, the VS 120 takes up to 7000 W and delivers 120 A. The larger model has two inputs, and wiring them in series raises Voc to 900 V. The battery window is 38–68 V. Conversion efficiency exceeds 98 %, MPPT tracking exceeds 99.8 %. Up to 15 units run in parallel, letting one battery collect power from several arrays. The VS 70 housing is IP54 and copes with a dusty room, while the VS 120 is IP20 and needs a dry location.

How to choose

Pick the model by array power, 4200 W for the VS 70 and 7000 W for the VS 120, then check cold-weather string Voc against 600 or 900 V. If panels sit next to the battery and strings are short, a VarioTrack with a 145–175 V input will do. A next3 system rarely needs a separate controller, since the inverter has two MPPT inputs of 8 kW.

Request a price and lead time

VarioString VS 70/120 — high-voltage MPPT charge controllers 48 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the maximum PV voltage of the VarioString VS 120?

Each input is rated 600 V Voc. With its two inputs in series the VS 120 accepts a string of up to 900 V.

Why does a charge controller need galvanic isolation?

It separates the high-voltage array from the 48 V bus, so an insulation fault on the roof does not put hazardous voltage on the battery and loads.

How many VarioString units can run in parallel?

Up to 15 units on one 48 V battery, the array power being the sum of all controllers.

What is the efficiency of the VarioString?

Conversion efficiency is above 98 % and maximum power point tracking accuracy is above 99.8 %.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.