Sunny Home Manager 2.0 — home energy manager

The Sunny Home Manager 2.0 (HM-20) home energy manager raises solar self-consumption and controls battery and EV charging with dynamic tariffs in mind. More than 420,000 units are installed, in private homes with PV, a battery, a heat pump or a charging station.

Functions
load and battery control, dynamic tariffs, price-based charging
Installed base
over 420,000 units

Technical specifications

Functionsload and battery control, dynamic tariffs, price-based charging
Installed baseover 420,000 units
More from the manufacturer’s documentation
Type designationHM-20
Software version (compatibility list)from 2.19.1.R
Load controldirect via EEBus or SEMP; indirect via radio-controlled sockets and relays
Compatible radio-controlled socketsEdimax, AVM, Niko, Shelly
Compatible metersEnergy Meter, elgris, Shelly
Heat pumpsSG-Ready; AEG Haustechnik, Stiebel Eltron, Tecalor, Vaillant, Wolf, Nibe
Home appliancesBosch and Siemens dishwashers, washing machines and dryers
Charging stations, Mennekes, Spelsberg
Heating rodsmy-PV
External system controlripple control receiver, export limitation per Section 9 EEG, controllable loads per Section 14a EnWG
Customs codes (for reference)
HS code9032.89
UKTZED code (Ukraine)9032890000
CN code (EU)90328900

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The device switches household loads on and off so they run during solar hours, and it starts battery or car charging when grid energy is cheaper. Compatible appliances are controlled directly over EEBus or SEMP, others through Edimax, AVM, Niko or Shelly radio-controlled sockets and relays. Heat pumps connect via SG-Ready, with AEG Haustechnik, Stiebel Eltron, Tecalor, Vaillant, Wolf and Nibe on the compatibility list, and surplus can go to a my-PV heating rod. Bosch and Siemens dishwashers, washing machines and dryers start on the manager signal. It runs EV charging on, Mennekes and Spelsberg stations. Power flow data comes from an Energy Meter, elgris or Shelly meter. The unit mounts on a DIN rail in the home distribution board, talks to the inverter and storage over the local network, and the compatibility list applies from firmware 2.19.1.R.

How to choose

The manager pays off when the house has controllable loads besides the inverter that can be shifted in time. For German sites it accepts a ripple control receiver signal, limits export per Section 9 EEG and controls loads per Section 14a EnWG. Before buying, check the heat pump, appliance and charging station brands against the compatibility list. For a commercial PV plant with dozens of inverters this unit is too small, so use the Data Manager M for 50 devices or the Data Manager L for 200 inverters.

Request a price and lead time

Sunny Home Manager 2.0 — home energy manager. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Does the Sunny Home Manager 2.0 work with dynamic tariffs?

Yes, it follows dynamic tariffs and charges the battery when grid energy is cheaper.

Can the Sunny Home Manager 2.0 control EV charging?

Yes, it controls battery and EV charging on, Mennekes and Spelsberg stations.

How many Sunny Home Manager 2.0 units are installed?

Over 420,000 units.

How does the Sunny Home Manager 2.0 control a heat pump?

Through the SG-Ready interface or directly over EEBus, so the pump runs during hours of solar surplus.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.