SPPC2000 / SPPC2000-MGCC power plant and microgrid controller
Country: China · Model: SPPC2000 / SPPC2000-MGCC
The cabinet controllers SPPC2000 and SPPC2000-MGCC manage solar plants with storage at the grid connection point and standalone microgrids with diesel generators. The power plant controller executes commands in 30–40 ms.
- SPPC2000 functions
- P/Q regulation, damping of oscillations at 0.1–2.5 Hz, response 30–40 ms
- MGCC functions
- on/off-grid transition 0 ms (planned), ≤ 200 ms (unplanned), black start, dispatching of PV + BESS + diesel generator
- Protocols
- Modbus-TCP, IEC 60870-5-104, GOOSE
- Measurement accuracy
- 0.2% (current/voltage)
Technical specifications
| SPPC2000 functions | P/Q regulation, damping of oscillations at 0.1–2.5 Hz, response 30–40 ms |
|---|---|
| MGCC functions | on/off-grid transition 0 ms (planned), ≤ 200 ms (unplanned), black start, dispatching of PV + BESS + diesel generator |
| Protocols | Modbus-TCP, IEC 60870-5-104, GOOSE |
| Measurement accuracy | 0.2% (current/voltage) |
| Ingress protection | IP55, C5-M |
| Dimensions / weight | 1000 × 650 × 650 mm, ≤ 80 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The SPPC2000 regulates the active and reactive power of the plant on the command of the grid operator and damps oscillations at 0.1–2.5 Hz. It measures current and voltage with an accuracy of 0.2%, which is sufficient to meet the power requirements at the connection point. The MGCC version manages a microgrid where solar plants, BESS and diesel generators operate, distributing the load among them. A planned transition between grid and island mode takes 0 ms, an unplanned one no longer than 200 ms, and the black start function brings up the microgrid after a complete blackout. Communication with the dispatch center and plant devices uses Modbus-TCP, IEC 60870-5-104 and GOOSE. The 1000 × 650 × 650 mm cabinet weighing up to 80 kg has IP55 protection and C5-M finish, so it can stand on an open site.
How to choose
For a plant connected to the grid, the SPPC2000 is sufficient, since its task is to execute P/Q commands and damp oscillations. If the site must operate in an island with a diesel generator, for example at a remote enterprise, the MGCC version with on/off-grid transition and black start is needed. Before ordering, check which protocol the operator SCADA supports, Modbus-TCP or IEC 60870-5-104.
Request a price and lead time
SPPC2000 / SPPC2000-MGCC power plant and microgrid controller. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the response time of the SPPC2000 controller?
The controller executes regulation commands in 30–40 ms.
How fast does the SPPC2000-MGCC switch a microgrid to island mode?
A planned transition takes 0 ms, an unplanned one up to 200 ms.
Which protocols does the SPPC2000 support?
Modbus-TCP, IEC 60870-5-104 and GOOSE for communication with the dispatch level and plant equipment.
Can the SPPC2000-MGCC be used with a diesel generator?
Yes, the controller dispatches solar plant, BESS and diesel generator in one microgrid and supports black start.
What is the measurement accuracy of the SPPC2000 controller?
Current and voltage measurement accuracy is 0.2%, and the cabinet weighs up to 80 kg.