Data Manager M / L — PV plant controller

Data Manager PV plant controllers handle monitoring and power control at the grid connection point, with the M version serving up to 50 devices and the L version up to 200 inverters. The M goes onto commercial plants and the L onto megawatt-class plants.

Data Manager M
up to 50 devices, digital and analog inputs/outputs
Data Manager L
up to 200 inverters, megawatt-class PV plants
Platform
ennexOS, Sunny Portal

Technical specifications

Data Manager Mup to 50 devices, digital and analog inputs/outputs
Data Manager Lup to 200 inverters, megawatt-class PV plants
PlatformennexOS, Sunny Portal
More from the manufacturer’s documentation
Data Manager M typeEDMM-20
Max. plant size (Data Manager M)7.5 MVA (from version 2.5.27.R)
Battery operating modesimport, export, peak load shaving; local time plans
CybersecurityRED, ETSI EN 303 645; network protocols encrypted by default (from version 2.6)
Network segregationbetween Internet and plant network without extra hardware (from version 2.6)
Charging station monitoringEV Charger Business and eCharger
StandardsUNE 217001:2020 (zero feed-in, Spain); load limitation per Section 14a EnWG via digital input
Customs codes (for reference)
HS code9032.89
UKTZED code (Ukraine)9032890000
CN code (EU)90328900

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Data Manager M (EDMM-20) has digital and analog inputs and outputs for grid operator commands and sensors, and from firmware 2.5.27.R it controls plants up to 7.5 MVA. Data Manager L targets large plants and works with inverters only. Both controllers run on ennexOS and send data to Sunny Portal, and through them the plant applies power limits and reactive power control. For storage, the controller sets import, export and peak shaving modes plus local time schedules. EV Charger Business and eCharger stations show up in the same portal. Zero feed-in follows the Spanish UNE 217001:2020 standard, and load limiting per Section 14a EnWG comes in through a digital input. From version 2.6, network protocols are encrypted by default and the internet is separated from the plant network with no extra hardware, in line with RED and ETSI EN 303 645.

How to choose

Choose the version by device count and inverter brand. A commercial rooftop with mixed equipment, meters, sensors and storage fits the M for 50 devices. A plant with more than 50 inverters, all of them, needs the L for 200 inverters. If you need telecontrol to a dispatch center or genset control, take the Power Plant Manager, and for a private home with a battery and a heat pump the Sunny Home Manager 2.0 is enough.

Request a price and lead time

Data Manager M / L — PV plant controller. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How many inverters does the Data Manager L support?

Up to 200 inverters, and it does not support third-party inverters.

How many devices connect to the Data Manager M?

Up to 50 devices, with digital and analog inputs and outputs. From firmware 2.5.27.R it handles plants up to 7.5 MVA.

Which monitoring portal does the Data Manager use?

Sunny Portal on the ennexOS platform.

Can the Data Manager M do zero feed-in?

Yes, it limits export to zero, including to the Spanish UNE 217001:2020 standard.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.