CHARGE CONTROLLERS AND EMS

I/O system 1000 and x750 gateway input/output modules

The I/O system 1000 is a modular input/output system for DIN rail, with modules 12.5 mm wide and 8 connection points. A head module EPM-S110, S120, S131 or S140 connects it to a CANopen, PROFIBUS, EtherCAT or PROFINET network. A separate x750 gateway links existing CAN networks to EtherCAT.

Head modules
EPM-S110 CANopen, EPM-S120 PROFIBUS, EPM-S131 EtherCAT, EPM-S140 PROFINET
Modules
digital with 2/4/8 inputs and outputs and others; width 12.5 mm, 8 connection points
Mounting
DIN rail
x750 gateway
EtherCAT–CAN, High Speed CAN up to 1 Mbit/s

Technical specifications

Head modulesEPM-S110 CANopen, EPM-S120 PROFIBUS, EPM-S131 EtherCAT, EPM-S140 PROFINET
Modulesdigital with 2/4/8 inputs and outputs and others; width 12.5 mm, 8 connection points
MountingDIN rail
x750 gatewayEtherCAT–CAN, High Speed CAN up to 1 Mbit/s

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The digital inputs EPM-S200…S210 come with 2, 4 or 8 channels, including with three-wire connection, negative switching, fast ones with a time of 2 µs and ones with a 0.5 ms filter. The digital outputs EPM-S300…S312 have 2, 4 or 8 channels for a 2 A current, relay ones for 230 V and fast 2 µs ones. The analogue inputs EPM-S400…S416 give 2 or 4 channels of 0…10 V, −10…+10 V and 0/4…20 mA, some of them 16-bit and galvanically isolated, and there are inputs for resistance thermometers, thermocouples and a strain gauge. A separate module measures a three-phase 230/400 V, 5 A mains. The analogue outputs EPM-S500…S505 have the same ranges, including 16 bit. There are 24 V modules for counters. The minimum cycle time together with time stamps is needed to read touch probe inputs for synchronous movements.

How to choose

First the head module is chosen for the controller bus, that is EPM-S110, S120, S131 or S140. Then the modules are selected by type and number of channels, and if a CAN network already runs in the machine and the controller speaks EtherCAT, the x750 gateway is installed instead of replacing equipment. In an EtherCAT network it behaves as an ordinary device, and the number of CAN nodes is limited only by the CANopen specification. The x750 gateway has High Speed CAN up to 1 Mbit/s, IP20 and a 24 V DC supply. Parameterisation and CANopen libraries are in PLC Designer, and remote access to the machine is provided by separate x500 IoT gateways.

Request a price and lead time

I/O system 1000 and x750 gateway input/output modules. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How wide are the I/O system 1000 modules?

12.5 mm with 8 connection points, mounted on a DIN rail.

Which head module is needed for EtherCAT?

The EPM-S131. For CANopen the EPM-S110 is taken, for PROFIBUS the EPM-S120, for PROFINET the EPM-S140.

Which signals do the EPM-S400…S416 analogue inputs accept?

0…10 V, −10…+10 V and 0/4…20 mA on 2 or 4 channels, and there are also inputs for resistance thermometers, thermocouples and a strain gauge.

How can a CAN network be connected to EtherCAT?

Through the x750 gateway with a High Speed CAN interface up to 1 Mbit/s. It needs a 24 V DC supply.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.