Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

CHARGE CONTROLLERS AND EMS

c250-S safety controller

c250-S is a DIN-rail safety controller for automation systems with IP20 protection and 24 V DC supply. It works as an EtherCAT slave and at the same time as an FSoE master, and the safety level corresponds to PL e / SIL 3.

Runtime
CODESYS
Connectivity
EtherCAT slave, EtherCAT FSoE master

Technical specifications

RuntimeCODESYS
ConnectivityEtherCAT slave, EtherCAT FSoE master

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The controller exchanges safe data with drives and I/O modules over EtherCAT using the FSoE protocol (Fail Safe over EtherCAT); the runtime is CODESYS. Together with safe I/O modules it evaluates all safety aspects of a machine module. The modules have removable connectors and are mounted directly next to each other, and the outputs are rated for current up to 2 A. Programming is done on a single engineering platform according to the PLCopen standard. The operating temperature is 0…+55 °C (3K3 per EN 60721-3-3), storage and transport are allowed at −25…+70 °C, pollution degree 2. CE and UKCA marking, UL and RoHS compliance.

How to choose

A safety controller is needed where safety functions must be processed centrally and passed to drives that support FSoE, for example i950 cabinet and 9400 HighLine servo inverters or i650 motec converters. It complements control and drives within one platform, and for motion control a c430, c520 or c550 is placed next to it.

Request a price and lead time

c250-S safety controller. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What safety level does the c250-S have?

The solution corresponds to level PL e / SIL 3.

What supply and protection rating does the c250-S have?

24 V DC supply, IP20 protection, DIN-rail mounting.

What safety protocol does the c250-S use?

FSoE (Fail Safe over EtherCAT). In the machine network the controller is an EtherCAT slave and at the same time an FSoE master.

What is the temperature range of the c250-S?

Operating 0…+55 °C, and storage and transport −25…+70 °C.

Which drives does the c250-S work with?

With drives that support FSoE, for example i950 cabinet and 9400 HighLine servo inverters or i650 motec converters.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.