SLC ENERGY MANAGER — smart meter for solar plant energy management
Country: Spain · Model: SLC ENERGY MANAGER
The SLC ENERGY MANAGER measures energy flows at the input of a solar installation and sends the data to EQUINOX2 inverters to control power flows and self-consumption. The meter is made in single-phase and three-phase versions, and the three-phase versions T and H are designed for 3×480 V.
- Version
- single-phase and three-phase (T, H 3×480 V), with current transformers
- Setup
- by cable or via WiFi, automatic configuration of current transformers
- Communication
- Modbus TCP
Technical specifications
| Version | single-phase and three-phase (T, H 3×480 V), with current transformers |
|---|---|
| Setup | by cable or via WiFi, automatic configuration of current transformers |
| Communication | Modbus TCP |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The current is measured through current transformers installed on the input cables. The device configures the current transformers by itself, so the installer does not need to set their parameters manually. Setup is done by cable or via WiFi. In the three-phase version measurement is made for each phase separately, which is needed for correct export limiting on an unbalanced input. The meter exchanges data with the inverter over Modbus TCP. By its readings the inverter limits the feed into the grid to zero or to a set limit, and a hybrid system determines when to charge the battery and when to give energy to consumers.
How to choose
The version is chosen by the input of the site: single-phase for a single-phase house, and T or H of 3×480 V for a three-phase enterprise. The current transformers must match the maximum input current. The meter is designed to work with EQUINOX2 inverters, and compatibility with other brands is checked separately.
Request a price and lead time
SLC ENERGY MANAGER — smart meter for solar plant energy management. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the SLC ENERGY MANAGER needed for in a solar plant?
It measures power flows at the input and sends them to EQUINOX2 inverters to control export to the grid and self-consumption.
What is the voltage of the three-phase SLC ENERGY MANAGER?
The three-phase versions T and H are designed for a 3×480 V network and work with current transformers.
How is the SLC ENERGY MANAGER meter set up?
By cable or via WiFi, and the current transformers are configured automatically.
Which protocol does the SLC ENERGY MANAGER use to communicate with the inverter?
The Modbus TCP protocol. Through it the inverter receives data on the input power.
Which inverters does the SLC ENERGY MANAGER work with?
The meter is made for solar installations with EQUINOX2 inverters, grid-tied and hybrid. Compatibility with other brands must be checked separately.