Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

CHARGE CONTROLLERS AND EMS

Mid-level Temperature Controller UT55A/UT52A

The UT55A and UT52A are mid-level temperature controllers with a large color 14-segment LCD. They run on 21.6 to 28.0 VDC, and indication accuracy is ±0.1% of full scale. The shallow case suits crowded instrument panels.

[Example of ladder instruction]
[Example of ladder programming]
Indication accuracy
±0.1% of F.S.
Algorithm
ON/OFF, PID (continuous, time-proportional), heating/cooling, position-proportional
Type
1 to 5 V, etc. Only 1 input can be changed to universal input when the /DR option is specified

Technical specifications

[Example of ladder instruction][Example of ladder programming]
Indication accuracy±0.1% of F.S.
AlgorithmON/OFF, PID (continuous, time-proportional), heating/cooling, position-proportional
Type1 to 5 V, etc. Only 1 input can be changed to universal input when the /DR option is specified
FunctionPV high, PV low, deviation high, etc.
Voltage21.6 to 28.0 VDC
MassMax 0.5 kg
TCK, J, T, B, S, R, N, E, L, U, W PL-2, PR20-40, W97Re3-W75Re25
RTDJPt100, Pt100
DC voltage0.4 to 2.0 V, 1.0 to 5.0 V, 0.0 to 2.0 V, 0 to 10 V, -10 to 20 mV, 0 to 100 mV
DC current4 to 20 mA, 0 to 20 mA

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Navigation keys beside the display make it easier to browse parameters and change settings, and the supported networks, Ethernet among them, open the way to a data acquisition system. Main inputs cover thermocouples K, J, T, B, S, R, N, E, L, U and the tungsten-rhenium types, Pt100 and JPt100 RTDs, 4 to 20 mA, 0 to 20 mA and voltage from 1 to 5 V up to 0 to 10 V. The base version takes a 1 to 5 V input; with the /DR option only 1 input switches to universal. Control can follow ON/OFF, PID, heating/cooling or position-proportional algorithms. The unit weighs at most 0.5 kg.

How to choose

First decide whether a single universal input, that the /DR option gives, is enough for you. Then check which of the two sizes, UT55A or UT52A, fits the panel cutout. The 21.6 to 28.0 VDC supply means an AC mains installation needs a separate power supply. When ladder logic and extended inputs are required, move up to the UT75A.

Request a price and lead time

Mid-level Temperature Controller UT55A/UT52A. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What supply voltage do the UT55A and UT52A need?

The supply is 21.6 to 28.0 VDC. A separate power supply is needed for an AC mains.

What does the /DR option do on the UT55A/UT52A?

With the /DR option, only 1 input can be changed to universal. The other inputs keep the type set in the base version.

What is the indication accuracy of the UT55A?

Indication accuracy is ±0.1% of full scale. The same value is given for the UT52A.

Can the UT55A be connected to Ethernet?

Yes, the UT55A and UT52A support open networks, including Ethernet communication. That is handy for sending data to SCADA or a recorder.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.