Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

DRIVES AND FREQUENCY CONVERTERS

Commander C200 / C300 — general-industrial frequency converters 0.25–132 kW, 110–400 V, with built-in PLC (C300 with dual STO)

Commander C200 and C300 are general-industrial frequency converters for 0.25–132 kW and 110–400 V mains with a built-in PLC. The C300 additionally has a dual safe torque off input. Drives of this kind have been made under the Commander brand since 1983, and this series is the sixth.

Power
0.25–132 kW
Supply
1×110, 1×230, 3×230, 3×400 V AC ±10 %
Overload
150 % for 60 s or 180 % for 3 s
Output frequency
0–550 Hz

Technical specifications

Power0.25–132 kW
Supply1×110, 1×230, 3×230, 3×400 V AC ±10 %
Overload150 % for 60 s or 180 % for 3 s
Output frequency0–550 Hz
ModesU/f, open-loop vector, sensorless RFC-A
SafetyC300: dual STO, SIL3/PLe, EN/IEC 61800-5-2
Built-inclass A EMC filter, braking transistor, PID, PLC (Machine Control Studio)
Options1 slot (from frame size 2): PROFIBUS, PROFINET, DeviceNet, CANopen, Ethernet, EtherCAT, SI-I/O; AI-Back-up, AI-485, AI-485 24V adapters
Protection ratingIP20
ReplacementC200 replaces the discontinued Commander SK

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Supply is 1×110, 1×230, 3×230 or 3×400 V ±10 %, output frequency 0–550 Hz, protection rating IP20. Overload of 150 % for 60 s or 180 % for 3 s suits machines with high starting torque. The control modes are U/f, open-loop vector and sensorless RFC-A, with speed and torque control. The drive has a built-in class A EMC filter, braking transistor, PID controller and a PLC in Machine Control Studio, so in many cases no external controller is needed. The C300 has a dual STO input with SIL3/PLe per EN/IEC 61800-5-2. From frame size 2 a slot is available for PROFIBUS, PROFINET, DeviceNet, CANopen, SI-Ethernet, EtherCAT and SI-I/O modules, and the AI-Back-up (SD card, 24 V backup supply), AI-485 and AI-485 24V adapters provide an RS485 port.

How to choose

The difference between the models is safety. The C200 is an economical vector drive, and the C300 adds a dual STO. The upper limit of the series is 132 kW; for higher power and closed loop, move to the Unidrive M600 or Unidrive SP. The C200 is a direct replacement for the discontinued Commander SK drives (SKA/SKB), so for a retrofit select it by motor current.

Request a price and lead time

Commander C200 / C300 — general-industrial frequency converters 0.25–132 kW, 110–400 V, with built-in PLC (C300 with dual STO). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the overload capacity of Commander C200?

150 % of rated current for 60 s or 180 % for 3 s. This is sufficient for machines with high starting torque.

What can replace the discontinued Commander SK drives?

The Commander C200 is a direct replacement for Commander SK drives (SKA/SKB).

What supply voltage does Commander C have?

Single-phase 1×110 or 1×230 V and three-phase 3×230 or 3×400 V AC with a tolerance of ±10 %.

How does C300 differ from C200?

The C300 has a dual safe torque off STO input, certified to SIL3/PLe per EN/IEC 61800-5-2.

Which machines is Commander C suitable for?

Pumps, fans and compressors with energy savings at low load, conveyors, hoists and winches.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.