Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

DRIVES AND FREQUENCY CONVERTERS

i510 cabinet frequency inverter for control cabinets 0.25–15 kW

The compact i510 cabinet frequency inverter, 0.25–15 kW, is for installation in a control cabinet and is the entry model of the i500 platform. It smoothly controls the speed of three-phase asynchronous motors in simple machines, including belt and roller conveyors, travel drives, pumps, fans and mixers. The housing has IP20 protection.

Power
0.25–15 kW
Mains
1×230 V: 0.25–2.2 kW; 3×230 V: 0.25–7.5 kW; 3×400/480 V: 0.37–15 kW
Protection rating
IP20
Inputs/outputs
5 DI, 1 DO, 2 AI, 1 AO, 1 relay

Technical specifications

Power0.25–15 kW
Mains1×230 V: 0.25–2.2 kW; 3×230 V: 0.25–7.5 kW; 3×400/480 V: 0.37–15 kW
Protection ratingIP20
Inputs/outputs5 DI, 1 DO, 2 AI, 1 AO, 1 relay
Operating temperature−20…+60 °C (derating 2.5 %/°C above +45 °C)
Energy efficiencyIE2 per EN IEC 61800-9-2
CertificatesCE, UKCA, cULus, RoHS

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The rectifier converts the mains voltage to DC, and the output IGBT inverter forms three-phase voltage of variable frequency and amplitude for the motor. U/f characteristic, vector control of asynchronous motors and vector control of synchronous motors are supported. There are slip compensation, boost, oscillation damping, skipping of resonance frequencies, a PID controller, fixed frequencies, a motor potentiometer, catching of a rotating motor, DC braking, holding brake control and the VFC eco mode. The housing is 60 mm wide for models up to 4 kW and 130 mm deep for models up to 11 kW, and side-by-side mounting is permitted. The control terminals have 5 digital inputs, 1 digital output, 2 analogue inputs, 1 analogue output and 1 relay output with a changeover contact. Of the fieldbuses, CANopen and Modbus RTU are available. The operating temperature per EN 60721-3-3 class 3K3 is −20 to +60 °C, and above +45 °C the current is derated by 2.5 %/°C. Commissioning and diagnostics are done from the keypad, via USB or over WLAN. The inverter meets EN IEC 61800-9-2 (class IE2) and carries CE, UKCA, cULus and RoHS marks.

How to choose

The mains and the power are selected together. Single-phase 230/240 V supply handles up to 2.2 kW, three-phase 230/240 V up to 7.5 kW, and three-phase 400/480 V up to 15 kW. If STO, Ethernet interfaces or higher power are needed, the higher model i550 cabinet is taken instead of the i510 cabinet.

Request a price and lead time

i510 cabinet frequency inverter for control cabinets 0.25–15 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power and supply does the i510 cabinet have?

A range of 0.25–15 kW. Single-phase 230/240 V mains for 0.25–2.2 kW, three-phase 230/240 V for 0.25–7.5 kW, three-phase 400/480 V for 0.37–15 kW.

How many inputs and outputs does the i510 cabinet have?

5 digital inputs, 1 digital output, 2 analogue inputs, 1 analogue output and 1 relay output with a changeover contact.

Which fieldbuses does the i510 cabinet support?

CANopen and Modbus RTU. For Ethernet interfaces and STO the higher model i550 cabinet is needed.

Can several inverters be mounted side by side?

Yes, side-by-side mounting is permitted. The housing is 60 mm wide for models up to 4 kW.

At what temperature does the i510 cabinet work?

From −20 to +60 °C per class 3K3. Above +45 °C the current is derated by 2.5 %/°C.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.