DRIVES AND FREQUENCY CONVERTERS
b maXX 5000 / 5100 DC link power supply units 5–200 kW, including with regeneration to the mains
Country: · Model: b maXX 5000 / 5100
b maXX 5000 and 5100 are DC link power supply units for a modular servo drive system. The 5000 series gives a 5–200 kW link and 7.5–300 kW peak, while the 5100 adds regeneration of braking energy to the mains at 36–200 kW. From one unit, single- and double-axis b maXX 5300 and 6300 modules are fed through a common link.
- b maXX 5000
- BM 5030…5075: link power 5–200 kW, peak 7.5–300 kW, overload 1.0–2.0
- b maXX 5100
- BM 5173, 5174, 5192, 5193: 36–200 kW, peak 54–300 kW, overload 1.5 (120 s) / 2 (10 s)
- Mains
- 207–528 V AC, nominal 400 V, 50/60 Hz
- DC link
- 640 V (5100, nominal)
Technical specifications
| b maXX 5000 | BM 5030…5075: link power 5–200 kW, peak 7.5–300 kW, overload 1.0–2.0 |
|---|---|
| b maXX 5100 | BM 5173, 5174, 5192, 5193: 36–200 kW, peak 54–300 kW, overload 1.5 (120 s) / 2 (10 s) |
| Mains | 207–528 V AC, nominal 400 V, 50/60 Hz |
| DC link | 640 V (5100, nominal) |
| Regeneration | sinusoidal return of braking energy to the mains (5100) |
| Safety | central STO module: SIL 2 (IEC 61508), PLd cat. 3 (EN ISO 13849-1) |
| Cooling | air, cold plate, water push-through |
| Dimensions | 75…425 × 395 × 210–280 mm |
| Certification | CE, cUL |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The 5000 series is a system rectifier in three frame sizes. The range includes the BM 5030 (5/7.5 kW), BM 5031 (10/15 kW), BM 5032 (18/27 kW), BM 5043 (36/54 kW), BM 5044 (70 kW), BM 5074 (150/300 kW, overload 2) and BM 5075 (200/300 kW). In the 5100 series, braking energy is not turned into heat in a braking resistor but is returned to the mains as sinusoidal current. The range BM 5173 (36/54 kW), BM 5174 (64/96 kW), BM 5192 (150/300 kW) and BM 5193 (200/300 kW) allows overload for up to 120 s, with a nominal DC link voltage of 640 V. Energy costs account for more than 90 % of the life-cycle cost of a drive, so regeneration noticeably reduces total costs.
How to choose
The modules are mounted directly next to the power supply unit and connected with the drive connect system, so an individual module can be removed or added without taking the whole system apart, and the number of axes depends on the link power. Mains voltage is 207–528 V AC (nominal 400 V), 50/60 Hz, and the electronics are supplied from an external 24 V DC. Cooling is by air, through a plate (cold plate) or by water using push-through technology. The central STO module switches off all motors in the power supply unit and meets SIL 2 per IEC 61508 or PLd cat. 3 per EN ISO 13849-1. The BM5-CAP capacitance module stores braking energy for the next acceleration, and the units are certified to CE and cUL.
Request a price and lead time
b maXX 5000 / 5100 DC link power supply units 5–200 kW, including with regeneration to the mains. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the difference between the b maXX 5000 and 5100?
The 5100 series returns braking energy to the mains as sinusoidal current, while the 5000 has no such regeneration.
What is the link power of the power supply units?
5–200 kW in the 5000 series with a 7.5–300 kW peak and 36–200 kW in the 5100 series with a 54–300 kW peak.
Which modules are fed by the unit?
Single- and double-axis b maXX 5300 and 6300 modules through a common DC link.
Which cooling methods are available?
Standard air, through a cooling plate (cold plate) and water push-through.
What is the BM5-CAP module for?
It stores braking energy for the next acceleration.
Similar products
TMdrive-10e2Low-voltage system VFD 460/575/690 V (including SPR and DP)
Perfect PitchElectric blade pitch systems for wind turbines 0.75–15 MW
FRENIC-MEGA (G2)General-purpose frequency converter 0.4–710 kW, 200/400 V
Commander / Unidrive M / Powerdrive MD Smart / DigistartLV frequency converters (Commander, Unidrive M, Powerdrive MD Smart) and Digistart D4/D5 soft startersREQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.