Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

DRIVES AND FREQUENCY CONVERTERS

i550 motec decentralised frequency inverter IP66 0.37–45 kW

The i550 motec decentralised frequency inverter, 0.37–22 kW at 3×230/240 V and 0.37–45 kW at 3×400/480 V, is mounted directly on the motor or on a wall. The IP66 housing (UL Type 4X for indoor use) makes a control cabinet unnecessary. The parameters and setup logic match the i500 cabinet inverters, so a project can be carried over between versions.

Power
3×230 V: 0.37–22 kW; 3×400/480 V: 0.37–45 kW
Mounting
on a wall or on the motor
Protection rating
IP66 (UL Type 4X indoor)
Communication
EtherCAT, EtherNet/IP, IO-Link, Modbus RTU/TCP, PROFINET

Technical specifications

Power3×230 V: 0.37–22 kW; 3×400/480 V: 0.37–45 kW
Mountingon a wall or on the motor
Protection ratingIP66 (UL Type 4X indoor)
CommunicationEtherCAT, EtherNet/IP, IO-Link, Modbus RTU/TCP, PROFINET
Optionsexpansion unit with switch, Type E
Operating temperature−30…+60 °C
CertificatesCE, UKCA, cULus, RoHS

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The drive is installed on the machine, so the motor cable becomes shorter and the machine is easily divided into independent modules, and connection is by standard plug connectors. For wall mounting there is an expansion unit with a disconnector, with or without a Type E combined starter, and with operating controls. The inputs and outputs are configurable in three versions. Standard-I/O has 4 DI or 3 DI and 1 DO, Application-I/O has 4 IO-Link ports and 8 DI or 4 DI and 4 DO, and Extended-I/O has 2 AI, 1 AO and 4 DI, two of which can be reconfigured as outputs. The four IO-Link ports work as a simplified IO-Link master for sensors and actuators. There are holding brake control, motor temperature monitoring and a USB-C port. Communication is via EtherCAT, EtherNet/IP, IO-Link, Modbus RTU, Modbus TCP, PROFINET and optionally CANopen. The built-in regeneration module returns braking energy, so a braking resistor is not needed. The operating temperature is −30 to +60 °C with derating of 2.5 %/°C above +40 °C, vibration resistance up to 1 g. The drive meets EN IEC 61800-9-2 (IE2) and carries CE, UKCA, cULus and RoHS marks.

How to choose

The choice depends on the set of inputs and outputs and on the mains. Standard-I/O suits simple tasks, Application-I/O adds four IO-Link ports, and Extended-I/O adds analogue inputs and an output. Power is taken by mains, up to 22 kW at 3×230/240 V and up to 45 kW at 3×400/480 V. STO is available as an option. The inverter is supplied separately and assembled with MF, m500, m550-U, m650-U and m550-V motors and with g500 geared motors.

Request a price and lead time

i550 motec decentralised frequency inverter IP66 0.37–45 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power does the i550 motec have?

0.37–22 kW at a 3×230/240 V supply and 0.37–45 kW at 3×400/480 V.

What protection rating does the i550 motec have?

IP66, and also UL Type 4X for indoor use. So the inverter is installed on the machine without a control cabinet.

Is a braking resistor needed?

No, the built-in regeneration module returns braking energy to the mains.

Which input/output versions are available?

Standard-I/O, Application-I/O and Extended-I/O. Application-I/O has 4 IO-Link ports.

What is the operating temperature?

From −30 to +60 °C, and above +40 °C the current is derated by 2.5 %/°C.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.