i510/i550 protec wall-mounted frequency inverter 0.37–75 kW

The i550 protec frequency inverters, 0.37–75 kW, and i510 protec, 0.37–11 kW, are mounted outside the control cabinet, on a wall, on the machine frame or next to the motor. The i550 protec housing has IP55/IP66 protection, and the i510 protec is built in IP20 per EN 60529. They are taken when there is no room in the cabinet or when the machine is divided into modules with their own drives.

Power
i550 protec: 0.37–75 kW; i510 protec: 0.37–11 kW
Mains
1×120/230 V, 3×230 V, 3×400/480 V, 3×600 V
Protection rating
i550 protec IP55/IP66; i510 protec IP20 (UL installation)
Operating temperature
−30…+60 °C

Technical specifications

Poweri550 protec: 0.37–75 kW; i510 protec: 0.37–11 kW
Mains1×120/230 V, 3×230 V, 3×400/480 V, 3×600 V
Protection ratingi550 protec IP55/IP66; i510 protec IP20 (UL installation)
Operating temperature−30…+60 °C
Inputs/outputs5 DI, 1 DO, 2 AI, 1 AO, 1 relay
CertificatesCE, UKCA, cULus, RoHS

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The electronics are the same as in the i510/i550 cabinet units of the i500 platform, with a changed housing and version. The i550 protec works from a 1×120 V mains at 0.37–1.1 kW, 1×230/240 V at 0.37–2.2 kW, 3×230/240 V at 0.37–45 kW, 3×400/480 V at 0.37–75 kW and 3×600 V at 0.75–45 kW. A maintenance switch and operating controls are connected through an expansion unit, versions with a keypad or a WLAN module are available, and there are a micro-USB diagnostic port, an IO-Link V1.1 interface, a DC bus and motor temperature monitoring. STO with SIL 3 per EN IEC 61508 and PL e per EN ISO 13849-1 is added as an option. Communication is via CANopen, EtherCAT, EtherNet/IP, Modbus RTU/TCP and PROFINET. The simpler i510 protec is supplied from 1×120/230 V, 3×230 V, 3×400/480 V and 3×600 V, communicates over CANopen and Modbus RTU and is started from the keypad, via USB or WLAN. In Europe it is not installed outside a cabinet, in the USA this is permitted (NEMA/UL Type 1).

How to choose

The protection rating decides first. For a machine in dust or splashes take the i550 protec, and for equipment under American requirements the i510 protec will also do. Above 11 kW only the i550 protec remains. The inputs and outputs are the same in both, namely 5 digital inputs, 1 digital output, 2 analogue inputs, 1 analogue output and a relay. Above +45 °C the load is derated by 2.5 %/°C. Both meet EN IEC 61800-9-2 (IE2) and have VFC eco and a PID controller.

Request a price and lead time

i510/i550 protec wall-mounted frequency inverter 0.37–75 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Can the i510 protec be installed outside a control cabinet?

Not in Europe, because an IP20 housing per EN 60529 is not intended for this. In the USA such installation is permitted under NEMA/UL Type 1.

Which communication interfaces does the i550 protec have?

CANopen, EtherCAT, EtherNet/IP, IO-Link, Modbus RTU/TCP and PROFINET.

Does the i550 protec have safe torque off?

Yes, the STO function with SIL 3 per EN IEC 61508 and PL e per EN ISO 13849-1 is available as an option.

What is the operating temperature of the drive outside a cabinet?

From −30 to +60 °C. Above +45 °C the power is derated by 2.5 % per degree.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.