Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

DRIVES AND FREQUENCY CONVERTERS

i700/i750 cabinet multi-axis servo inverters up to 30 kW

The multi-axis servo inverters i750 cabinet and i700 cabinet are installed in a control cabinet with a common DC bus of 260–775 V. Single-axis i750 modules cover 1.1–30 kW, dual-axis 1.1–7.5 kW, and the previous i700 series goes up to 15 kW.

Power
i750: 1.1–30 kW (3×230 V and 3×400/480 V); i700: up to 15 kW
Design
single- and dual-axis modules, width from 50 mm (i700)
Safety
STO
Rated DC bus current
30 and 60 A

Technical specifications

Poweri750: 1.1–30 kW (3×230 V and 3×400/480 V); i700: up to 15 kW
Designsingle- and dual-axis modules, width from 50 mm (i700)
SafetySTO
Rated DC bus current30 and 60 A
Degree of protectionIP20
CommunicationEtherCAT
FeedbackHIPERFACE DSL (OCT), resolver, SinCos, EnDat, SSI, TTL
Operating temperature−10…+55 °C

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The supply module is connected to the mains, and the single- and dual-axis modules take DC voltage from it. The supply modules have a DC output, a rated bus current of 30 and 60 A, a 3×230/400/480 V input, an output for a brake resistor, and 3 DI and 2 DO with fixed assignment. The axis modules withstand repeated overload with peak currents of 5–109 A, the dual-axis ones up to 32 A. The dual-axis module is 50 mm wide, plus 50 mm for the supply module. Single-cable OCT technology on HIPERFACE DSL, according to the manufacturer, halves the installation costs, and the extended safety functions cover SLS, SDI and SLP. Auto-tuning optimizes the drive in about 60 seconds. Communication is over EtherCAT, and feedback is read by a resolver, multi-encoder, HIPERFACE DSL, SinCos, EnDat, SSI and TTL. Motion control is built with controllers and the FAST Application Software package. The temperature is −10…+55 °C, derating is needed above +40 °C; marking CE, UKCA, cULus, RoHS, compliance with EN IEC 61800-9-2 (IE2).

How to choose

New projects start with i750 with the SLS, SDI and SLP functions. The i700 series has single-axis modules of 0.75–15 kW, dual-axis modules of 0.75–7.5 kW, the STO function and 2 digital inputs, and it is taken for a cabinet where it is already installed. For 45–110 kW the manufacturer recommends i950 cabinet, and for separate converters without a common bus up to 45 kW the 8400 is suitable. Paired with MCS and m850 servo motors, the servo inverters are used in positioning, robotics and packaging machinery.

Request a price and lead time

i700/i750 cabinet multi-axis servo inverters up to 30 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power do i750 cabinet modules have?

Single-axis 1.1–30 kW, dual-axis 1.1–7.5 kW, mains 3×230 or 3×400/480 V.

What is the voltage range of the common DC bus?

260–775 V. The supply modules have a rated bus current of 30 and 60 A.

What is the width of the dual-axis module?

50 mm, and the supply module takes another 50 mm. This is taken into account when laying out the cabinet.

What safety functions are in the i700 and i750 series?

The i700 has STO, and the i750 has the extended functions SLS, SDI and SLP.

Which communication network and sensors do the servo inverters support?

Communication over EtherCAT. Feedback is read by a resolver, multi-encoder, HIPERFACE DSL, SinCos, EnDat, SSI and TTL.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.