Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

DRIVES AND FREQUENCY CONVERTERS

i950 cabinet servo inverter for control cabinets 0.37–110 kW

The i950 cabinet servo inverter for installation in a control cabinet covers powers from 0.37 to 110 kW and is intended for multi-axis machines that need precise dynamic motion control. It works as an actuating drive under a higher-level controller or stand-alone on its own built-in logic.

Power
1×230 V: 0.37–1.5 kW; 3×230 V: 0.37–5.5 kW; 3×400/480 V: 0.55–110 kW
Degree of protection
IP20
Communication
EtherCAT, EtherNet/IP, PROFINET, PROFIBUS, CANopen
Safety
FSoE, PROFIsafe, operation with a safety PLC

Technical specifications

Power1×230 V: 0.37–1.5 kW; 3×230 V: 0.37–5.5 kW; 3×400/480 V: 0.55–110 kW
Degree of protectionIP20
CommunicationEtherCAT, EtherNet/IP, PROFINET, PROFIBUS, CANopen
SafetyFSoE, PROFIsafe, operation with a safety PLC
FeedbackHIPERFACE DSL (OCT, up to 22 kW), resolver, SinCos, EnDat, SSI, TTL/HTL
Operating temperature−10…+55 °C
CertificatesCE, UKCA, cULus, RoHS

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The power depends on the supply network. For 1×230/240 V it is 0.37–1.5 kW, for 3×230/240 V 0.37–5.5 kW, for 3×400/480 V 0.55–110 kW. For axis modules with multiple overload capacity, up to 250 kW is named in the description. The IP20 enclosure is intended only for installation in a cabinet. The design is modular. A feedback module and a bus module (CAN/CANopen, PROFIBUS, PROFINET, EtherCAT or EtherNet/IP) are selected for the machine, and standard profiles such as CiA 402 depend on the protocol, so there are fewer drive variants in stock. For feedback there is a multi-encoder input, a resolver and single-cable OCT technology with HIPERFACE DSL and EnDat 3 up to 22 kW; also HIPERFACE SinCos, EnDat 2.1/2.2, SSI, TTL and HTL. There are four digital inputs (optionally 5/4) and one analog input, protection against earth fault, short circuit and overvoltage, and the motor is monitored by PT1000 and I²t. Sensorless control works with IE5/IE6 synchronous reluctance motors of the m550 and m650 series.

How to choose

Choose by the network and power from the table, and by the bus and encoder type. For ordinary speed control up to 45 kW without complex motion, the 8400 BaseLine/StateLine/HighLine/TopLine for 0.25–45 kW is enough. A multi-axis system on a common DC bus is built on i700/i750 (1.1–30 kW), and a single drive up to 240 kW on 9400 HighLine.

Request a price and lead time

i950 cabinet servo inverter for control cabinets 0.37–110 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which motors are connected to the i950 cabinet servo inverter?

MCS, MCA, MQA, m850 and SDSGA servo motors. Sensorless control is provided for IE5/IE6 synchronous reluctance motors of the m550 and m650 series.

What is the operating temperature of i950 cabinet and when is derating needed?

The range is −10…+55 °C. Above +45 °C the power is derated by 2.5 % per degree.

What level of functional safety is available?

The built-in safety optionally complies with SIL 3/PL e, cat. 4. FSoE and PROFIsafe are available.

What certificates and standards does i950 cabinet have?

The drive complies with the Ecodesign Directive and EN IEC 61800-9-2 (IE2), and has CE, UKCA, cULus and RoHS.

Does i950 cabinet have cybersecurity?

Yes, cybersecurity functions appeared with firmware 2.0, and CRA compliance is stated from 2027.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.