Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

ELECTRIC MOTORS

TEXP explosion-proof NEMA Premium motors 1–400 hp (Class I, Div. 1)

Explosion-proof low-voltage induction motors of the NEMA Premium class at 1–400 hp for Division 1 areas, where an explosive atmosphere may be present in normal operation. Totally enclosed fan cooled explosion-proof version, speeds of 3600, 1800, 1200 and 900 rpm. They are installed at refineries, petrochemical and chemical plants and gas compressor stations.

Power
1–400 hp
Speed
3600 / 1800 / 1200 / 900 rpm
Explosion protection
Class I, Div. 1, Groups C, D and Class II, Groups E, F, G (up to 256T); Class I, Div. 1, Group D and Class II, Groups E, F, G (from 284T)
Temperature class
T2D / T3B

Technical specifications

Power1–400 hp
Speed3600 / 1800 / 1200 / 900 rpm
Explosion protectionClass I, Div. 1, Groups C, D and Class II, Groups E, F, G (up to 256T); Class I, Div. 1, Group D and Class II, Groups E, F, G (from 284T)
Temperature classT2D / T3B
Winding wireinverter duty, withstands peaks up to 2200 V
EfficiencyNEMA Premium
EnclosureTEFC explosion-proof

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Motors up to and including frame size 256T are certified for Class I, Division 1, Groups C and D (gases and vapors) and Class II, Groups E, F and G (combustible dust) with temperature codes T2D/T3B. From frame size 284T the certification covers Class I, Division 1, Group D and Class II, Groups E, F and G with the same codes. The inverter duty class winding wire withstands voltage pulses up to 2200 V, so the motors can be fed from a VFD within the stated control range. The series includes versions with a C-Face flange and in a round body for pumps and gearboxes. The motors are also used at oil and gas production sites, in paint shops, at grain elevators and flour mills. They are part of the stock program in the USA and are supplied from stock.

How to choose

The main thing when choosing is the explosion group and frame size. Up to 256T the certification covers groups C and D, and from 284T only group D, so for group C gases motors of frame size up to 256T are taken. If the area is Division 2 and an explosion-proof enclosure is not needed, look at the MAX-E1 or MAX-E2/841. When supplying from a VFD, note that the winding is rated for peaks up to 2200 V.

Request a price and lead time

TEXP explosion-proof NEMA Premium motors 1–400 hp (Class I, Div. 1). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which areas are the TEXP motors suitable for?

For Division 1 areas, where an explosive atmosphere may be present in normal operation, and also for combustible dust Class II, Groups E, F and G.

How does the TEXP certification up to 256T differ from that from 284T?

Up to and including 256T the motors have Class I, Division 1, Groups C and D. From 284T only Group D is certified, while for dust Class II, Groups E, F and G it applies in both cases.

Can the TEXP motors be fed from a frequency converter?

Yes, within the control range set by the manufacturer. The inverter duty winding wire withstands voltage peaks up to 2200 V.

What are the power and speed in the TEXP series?

From 1 to 400 hp at 3600, 1800, 1200 and 900 rpm in the totally enclosed fan cooled explosion-proof version.

Is there a TEXP with a flange or a round body?

Yes, there are versions with a C-Face flange and a round body for pumps and gearboxes.

Similar products

Electric motors

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.