Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

ELECTRIC MOTORS

KD1 / KD2 (LV) low-voltage flameproof motors Ex db / Ex db eb 0.12–800 kW

Low-voltage three-phase squirrel-cage induction motors in a flameproof enclosure for gas zone 1, rated 0.12–800 kW and 200–690 V. Marking II 2G Ex db IIB or IIC T3/T4 Gb, and Ex db eb with an increased-safety terminal box.

Series
KD1, KD2
Shaft height
63–500
Power
0.12–800 kW
Voltage
200–690 V (grid and converter)

Technical specifications

SeriesKD1, KD2
Shaft height63–500
Power0.12–800 kW
Voltage200–690 V (grid and converter)
Number of poles2–16
Explosion protectionII 2G Ex db IIB/IIC T3/T4 Gb; II 2G Ex db eb IIB/IIC T3/T4 Gb
CoolingIC410, IC411, IC416, IC418
Housingcast iron
Protection degreeIP55, IP56, IP65, IP66
Insulation155 (F)/130 (B) or 180 (H)/155 (F)
MountingB14, B18, B3, B35, B5, V1, V5, V6, V18
CertificationATEX, IECEx

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Shaft height 63–500, from 2 to 16 poles, cast iron frame. Cooling is IC410, IC411, IC416 or IC418, protection degree IP55, IP56, IP65 or IP66. Insulation is class 155 (F) used to 130 (B) or 180 (H) used to 155 (F). Mounting versions are B14, B18, B3, B35, B5, V1, V5, V6 and V18. The motors are ATEX certified, IECEx certification is possible, and the production holds an ATEX quality assurance notification (QAN) and an IECEx QAR report. The manual for enclosed IP55 motors contains a section on installation, connection, protection against impermissible heating and repair of category 2 and 3 machines for zones 1 and 2. The plant has belonged to a larger group since 2011.

How to choose

Power and shaft height are taken from the driven machine, and the Ex db or Ex db eb variant from the terminal box needed. For pumps, compressors, fans and mixers in oil and gas, refining, chemical and pharmaceutical production, fuel stores and other gas-hazardous rooms this series is suitable. The high-voltage KD2 version at 3–11 kV and 180–1320 kW is given as a separate item, and for gas and dust zones at once there is WEX3. The series replace flameproof motors AIM, VA, 2V and VAO.

Request a price and lead time

KD1 / KD2 (LV) low-voltage flameproof motors Ex db / Ex db eb 0.12–800 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What explosion-protection marking do KD1 and KD2 motors have?

II 2G Ex db IIB or IIC T3/T4 Gb, and also Ex db eb with an increased-safety terminal box. The motors are intended for gas zone 1.

What is the power and voltage range?

0.12–800 kW at 200–690 V from the grid or a frequency converter, shaft height 63–500.

What certificates do these motors have?

The motors are ATEX certified, and IECEx certification is possible. The production holds an ATEX quality assurance notification (QAN) and an IECEx QAR report.

What protection degrees and cooling schemes are available?

IP55, IP56, IP65 and IP66 with cooling IC410, IC411, IC416 or IC418.

Is there a high-voltage version of KD2?

Yes, the high-voltage KD2 version at 3–11 kV and 180–1320 kW is given as a separate item.

Similar products

Electric motors

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.