Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

ELECTRIC MOTORS

HAW12 – HAW29 — induction motors for drilling rigs 600–2000 hp, 575 V

HAW12 – HAW29 induction motors for 600–2000 hp at 575 V for drilling rigs powered from a 40 Hz frequency converter. They drive the top drive, rotary table, drawworks and mud pump. Intra-slot cooling gives more power and torque in the frame of a standard motor.

Models
HAW12 (600 hp), HAW13 (800 hp), HAW20 and HAW22 (1150 hp), HAW29 (2000 hp)
Voltage
575 V ±10 % (HAW13: 592 V)
Full-load current
540 A (HAW12) – 1590 A (HAW29)
Frequency
40 Hz rated, supplied from a VFD

Technical specifications

ModelsHAW12 (600 hp), HAW13 (800 hp), HAW20 and HAW22 (1150 hp), HAW29 (2000 hp)
Voltage575 V ±10 % (HAW13: 592 V)
Full-load current540 A (HAW12) – 1590 A (HAW29)
Frequency40 Hz rated, supplied from a VFD
Torque2690 lb-ft (HAW12) – 9500 lb-ft (HAW29)
Speedrated 795–1181 rpm, max. 2300–3000 rpm
Windingform wound, 6 poles (HAW13: 4), insulation class H, VPI
ProtectionIP23 or IP44, terminal box IP44 / IP56, IC06
Applicationstop drive, rotary table, drawworks, mud pump
CertificationATEX, IECEx, CSA, ABS, DNV on request; ISO 9001:2015 factory

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The patented intra-slot cooling keeps the motor cooler, so the HAW12 gives up to 50 % more power and torque than comparable machines, and the HAW13 up to 33 %, that is, 800 hp in the frame of a 600 hp motor. This way an existing rig is upgraded without changing equipment. The HAW12 has 575 V, 540 A, 1172/2340 rpm and 2690 lb-ft. The HAW13 has 592 V, 686 A, 1181/2400 rpm and 3560 lb-ft. The 1150 hp HAW20 gives 1120 A, 795/2300 rpm and 7610 lb-ft, the HAW22 of the same power 795/3000 rpm and 7680 lb-ft, and the 2000 hp HAW29 1590 A, 795/3000 rpm and 9500 lb-ft. The stator has form-wound windings for 6 poles (4 in the HAW13), class H insulation, Mica-Kapton tape and full vacuum pressure impregnation. Shafts are of 4140/4340 steels, with six 100 Ω platinum RTDs (two per phase), a space heater, IP23 or IP44, and IC06 cooling.

How to choose

The model is selected by power and purpose. The HAW12 and HAW20 are installed in the top drive, the HAW22 and HAW29 on a drawworks or pump, and the HAW13 gives 800 hp in the frame of a 600 hp motor. Options include an encoder, bearing temperature sensors, a blower unit, an air pressure switch, an IP56 terminal box, an insulated bearing and a double shaft end.

Request a price and lead time

HAW12 – HAW29 — induction motors for drilling rigs 600–2000 hp, 575 V. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power are HAW drilling motors made for?

From 600 hp (HAW12) to 2000 hp (HAW29). The motors are installed on more than 600 rigs.

What supply voltage do HAW12 – HAW29 motors have?

575 V ±10 %, and for the HAW13 the voltage is 592 V. Rated frequency is 40 Hz, supplied from a frequency converter.

What protection rating and insulation class do the motors have?

IP23 or IP44, terminal box IP44 or IP56, IC06 cooling. Class H insulation, VPI impregnation.

Are certificates for hazardous areas available?

ATEX, IECEx, CSA, ABS and DNV certificates are provided on request. The factory quality system is certified to ISO 9001:2015.

Similar products

Electric motors

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.