Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

ELECTRIC MOTORS

LSA 49.3 – LSA 54.2 (LV) large low-voltage synchronous generators, 730–5200 kVA

Large low-voltage synchronous generators LSA 49.3, 50.2, 52.3, 53.2 and 54.2 rated 730–5200 kVA for diesel and gas power plants, data centres, oil and gas facilities and ships. Four-pole, 1500–1800 rpm, efficiency up to 97.7 %, IP23 protection. Power is given in kVA at 50 Hz and in kW at 60 Hz.

Frame sizes
LSA 49.3 (730–1000 kVA), 50.2 (1100–1640), 52.3 (1860–2750), 53.2 (2000–4300), 54.2 (3500–5200 kVA)
Voltage
220–480 V (LSA 52.3 — 380–480 V; LSA 54.2 — 400–480 V)
Poles / speed
4 poles, 1500–1800 rpm
Shaft height
400 mm (49.3), 450 mm (50.2, 52.3), 500 mm (53.2, 54.2)

Technical specifications

Frame sizesLSA 49.3 (730–1000 kVA), 50.2 (1100–1640), 52.3 (1860–2750), 53.2 (2000–4300), 54.2 (3500–5200 kVA)
Voltage220–480 V (LSA 52.3 — 380–480 V; LSA 54.2 — 400–480 V)
Poles / speed4 poles, 1500–1800 rpm
Shaft height400 mm (49.3), 450 mm (50.2, 52.3), 500 mm (53.2, 54.2)
Max. efficiency96.9 % (49.3) – 97.7 % (53.2)
ExcitationAREP, PMG; AREP + PMI (52.3–54.2)
RegulatorsD350 / D550
Regulation accuracy±0.25 %
Short-circuit current300 % of rated, 10 s
Insulation / protectionclass H, IP23
AlsoLS 641–941 (Americas) in LV versions from 367 V

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

LSA 49.3 delivers 730–1000 kVA with a shaft height of 400 mm, efficiency up to 96.9 % and 220–480 V. LSA 50.2 rated 1100–1640 kVA has 450 mm and efficiency up to 97 %. LSA 52.3 rated 1860–2750 kVA, 450 mm, up to 97.5 % at 380–480 V. LSA 53.2 rated 2000–4300 kVA (class H temperature rise at 40 °C), 500 mm, up to 97.7 % at cos φ = 1. LSA 54.2 rated 3500–5200 kVA, 500 mm, up to 97.5 % at 400–480 V. Class H insulation, 2/3 winding pitch, 6 terminals (12 optional on LSA 49.3 and 50.2), operation up to 1000 m, overspeed 2250 rpm. Air flow ranges from 1 m³/s on LSA 49.3 to 2.5–2.8 m³/s on LSA 52.3. Excitation is AREP or PMG, and LSA 52.3–54.2 use AREP with a permanent magnet inductor PMI. Regulators D350 or D550 hold an accuracy of ±0.25 % and a short-circuit current of 300 % for 10 s, and the D550 adds grid parallel operation, three-phase sensing, a data log and remote communication. SAE flanges 0, 00, 1 and 1/2, discs 14–24, single- or two-bearing design.

How to choose

Choose the frame size by power, with shaft height rising from 400 to 500 mm. For data centres that need low reactances, the American market offers LS 641 (1450–2500 kW), LS 661 (700–2200 kW, 6 poles), LS 841 (1800–3000 kW) and LS 941 (2600–5000 kW) with PMG and D550, and their voltage starts at 367–400 V. Options cover other voltages, heating, winding protection at humidity above 95 % and air filters that derate power by 5 or 10 %.

Request a price and lead time

LSA 49.3 – LSA 54.2 (LV) large low-voltage synchronous generators, 730–5200 kVA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power do LSA 49.3 – LSA 54.2 generators have?

From 730 kVA (LSA 49.3) to 5200 kVA (LSA 54.2), four poles, 1500–1800 rpm.

What is the efficiency of LSA 49.3 – LSA 54.2 generators?

Up to 96.9 % for LSA 49.3 and up to 97.7 % for LSA 53.2 at cos φ = 1.

Which voltage regulators are fitted to LSA 49.3 – LSA 54.2?

D350 or D550 with ±0.25 % accuracy. The D550 supports grid parallel operation and has a data log.

How are large LSA generators excited?

AREP or PMG, and LSA 52.3, 53.2 and 54.2 use AREP with a permanent magnet inductor PMI.

What short-circuit current does the generator withstand?

300 % of rated current for 10 s. Class H insulation, IP23 protection.

Similar products

Electric motors

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.