Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

ELECTRIC MOTORS

MKG / MKP — low-voltage finned and air-cooled induction motors 55–1600 kW (including smoke extraction)

MKG and MKP are three-phase low-voltage squirrel-cage induction motors of 55–1600 kW, with a voltage up to 1 kV and a rotational speed up to 3600 rpm. Air cools them through the frame. MKP is designed for smoke extraction fans that work in a flow of hot gases.

MKG
55–1600 kW, up to 1 kV, frame size 200–560, IC411 (TEFC), IM B3/B5/V1, insulation H
MKP
100–1500 kW, up to 1 kV, frame size 315–560, IC418 (TEAO), IM B5/V1, insulation H
Rotational speed
up to 3600 rpm
Starting
DOL, soft start, frequency converter

Technical specifications

MKG55–1600 kW, up to 1 kV, frame size 200–560, IC411 (TEFC), IM B3/B5/V1, insulation H
MKP100–1500 kW, up to 1 kV, frame size 315–560, IC418 (TEAO), IM B5/V1, insulation H
Rotational speedup to 3600 rpm
StartingDOL, soft start, frequency converter
Protection degreeup to IP55
Smoke extraction (MKP)per EN 12101-3 up to 400 °C / 2 h
Special versions (MKG)ATEX, IECEx, marine, nuclear power plants
StandardsIEC 60034, NEMA MG1

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

MKG has a finned self-ventilated frame (IC411, TEFC), IEC frame sizes 200–560 and power ratings of 55–1600 kW. The mounting versions are IM B3 (IM1001), IM B5 (IM3001), IM V1 (IM3011) and special ones on request, with protection up to IP55 and class H insulation. MKP has no fan of its own and is cooled by an air flow from the driven fan (IC418, TEAO), with frame sizes 315–560, power 100–1500 kW and IM B5 and IM V1 versions. For smoke extraction it meets the temperature classes of EN 12101-3 up to 400 °C for 2 hours, and the absence of a fan makes it easier to build into the housing of an axial fan. Direct starting, soft starting and a frequency converter are allowed. The motors are made to IEC 60034 or NEMA MG1, and MKG has special ATEX, IECEx, marine and nuclear power plant versions; the nuclear overview for MKG/HKG states up to 2500 kW, up to 13.8 kV and frame sizes 250–630 (the high-voltage HKG is a separate item).

How to choose

If you need self-ventilation and power up to 1600 kW, MKG with an IC411 frame is used. For a smoke extraction fan, where the motor sits in the hot flow, you need MKP per EN 12101-3. Both series replace large 0.4–0.69 kV motors of the 5AM and AIR types. For water cooling, look at MKH motors with a water jacket up to 2000–2500 kW of class IE4.

Request a price and lead time

MKG / MKP — low-voltage finned and air-cooled induction motors 55–1600 kW (including smoke extraction). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How does MKG differ from MKP?

MKG has its own self-ventilation (IC411, TEFC), while MKP is cooled by an air flow from the driven fan (IC418, TEAO).

What is the power range of MKG and MKP?

MKG covers 55–1600 kW, MKP 100–1500 kW. They are installed in pumps, fans, compressors and mills.

Is MKP suitable for smoke extraction?

Yes, the design meets the temperature classes of EN 12101-3 up to 400 °C for 2 hours for operation in hot gases during a fire.

Can the motor be started from a frequency converter?

Yes, direct starting, soft starting and a frequency converter are allowed, with a rotational speed up to 3600 rpm.

Which mounting versions are available?

For MKG IM B3, IM B5 and IM V1, for MKP IM B5 and IM V1. Protection up to IP55, class H insulation.

Similar products

Electric motors

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.