Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

ELECTRIC MOTORS

MEBSGR wound-rotor induction motors with ribbed housing (IC411) up to 1200 kW

Three-phase wound-rotor induction motors with slip rings in a ribbed housing with IC411 cooling, rated up to 1200 kW in frames 200–560. They are made for voltages from 230 V to 13.8 kV, and the low-voltage catalogue gives stator voltages of 230, 400, 500 and 690 V.

Voltage
230 V – 13.8 kV (LV catalogue: stator 230, 400, 500, 690 V)
Power
up to 1200 kW
Frame
200–560
Cooling
IC411

Technical specifications

Voltage230 V – 13.8 kV (LV catalogue: stator 230, 400, 500, 690 V)
Powerup to 1200 kW
Frame200–560
CoolingIC411
Protection degreeIP55, optionally IP65
Housinggrey cast iron with cast feet (optionally welded)
Insulationclass F, used to B
MountingIM B3 (optionally IM B35)
Overload1.5 × In for up to 2 min once per hour
Bearingsrolling bearings with lubricating device

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Wound-rotor motors are chosen where high starting and breakaway torques are needed, sudden load shocks occur, the machine has a large moment of inertia or the grid is weak. The grey cast iron housing with cast feet (optionally welded) is torsionally stiff, resistant to vibration, cools well and is self-cleaning. Terminal boxes turn through 4 × 90°, and PTC thermistors are led to the box on the slip ring side. The standard mounting is IM B3, with special ones, for example IM B35, on request. Protection degree is IP55, optionally IP65, with class F insulation used to class B. Rolling bearings with lubricating devices are selected with a margin, which lowers maintenance costs.

How to choose

Powers are given for duty S1 at 40 °C and altitude 1000 m. Permissible current overload is 1.5 × In for up to 2 min once per hour. The motors are made to EN 60034 and IEC 60034. Typical drives are mills, crushers, shredders and refiners in the cement, paper and metallurgical industries and water management. The series replaces wound-rotor motors 4AK, AK and MTN when modernising heavy drives.

Request a price and lead time

MEBSGR wound-rotor induction motors with ribbed housing (IC411) up to 1200 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

When is a wound-rotor motor chosen instead of a squirrel-cage one?

With high starting torques, sudden load shocks, a large moment of inertia of the machine or a weak grid. A low starting current relative to power is also needed.

What is the maximum power and what frames does MEBSGR have?

Up to 1200 kW in frames 200–560, with IC411 cooling.

What stator voltages are in the low-voltage catalogue?

230, 400, 500 and 690 V. The whole series is made from 230 V to 13.8 kV.

What overload is permitted?

Current of 1.5 × In for up to 2 min once per hour. Power is given for duty S1.

What protection degree and mounting?

IP55, optionally IP65. Standard mounting IM B3, others, for example IM B35, on request.

Similar products

Electric motors

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.