SG / SGM / DB / OB dielectric gloves class 1–4 and dielectric boots and overshoes class 1–3 (7.5–36 kV)

SG dielectric gloves of classes 1–4 are rated for a working voltage from 7 500 to 36 000 V AC, and DB boots and OB overshoes of classes 1–3 for 7.5–26.5 kV. They are used for work in electrical installations above 1 kV, in 6–35 kV switchgear and on overhead lines, during switching and testing.

Gloves, standard
IEC 60903 / EN 60903, natural latex, category RC
Class 1 (SG-10)
working 7 500 V, proof test 10 000 V, withstand 20 000 V AC; thickness < 2.1 mm
Class 2 (SG-20)
17 000 / 20 000 / 30 000 V; < 2.9 mm
Class 3 (SG-30)
26 500 / 30 000 / 40 000 V; < 3.5 mm

Technical specifications

Gloves, standardIEC 60903 / EN 60903, natural latex, category RC
Class 1 (SG-10)working 7 500 V, proof test 10 000 V, withstand 20 000 V AC; thickness < 2.1 mm
Class 2 (SG-20)17 000 / 20 000 / 30 000 V; < 2.9 mm
Class 3 (SG-30)26 500 / 30 000 / 40 000 V; < 3.5 mm
Class 4 (SG-40)36 000 / 40 000 / 50 000 V; < 4.2 mm
SGMcomposite (latex + polychloroprene), electrical, mechanical and arc protection without over-gloves
Boots DB2 / DB3class 2 – 17.5 kV, class 3 – 26.5 kV; ASTM F1117 (20 kV), ASTM F2413; DB3 flexible to −40 °C
Overshoes OB1 / OB2 / OB3classes 1 (7.5 kV), 2 (17.5 kV), 3 (26.5 kV), moulded one-piece, SRC sole; OB1 – HRO 300 °C / 60 s

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The latex gloves comply with IEC 60903 / EN 60903, and the class is determined by thickness, because a thicker wall has higher electrical resistance. For the whole series the following are specified: tensile strength from 16 MPa, elongation from 600 %, puncture resistance from 18 N/mm, permanent set up to 15 %, conditioning for 24 h at −40 °C and a flame test of 10 s. Leather over-gloves SG are recommended over the latex and SG-37 Nomex gloves under it, while composite SGM with an outer layer of polychloroprene give electrical, mechanical and arc protection without separate over-gloves. Every pair of DB2 boots with a blue vulcanised sole is tested at 20 kV, with a leakage current below 5 mA at 5 kV and 18 mA at 20 kV, and the boots comply with ASTM F1117 and ASTM F2413. The moulded one-piece OB2 have no metal parts, and the fluorescent green OB3 with rear entry comply with REACH.

How to choose

The class is chosen so that the maximum working voltage of the gloves is not lower than the voltage of the installation. The working, proof test and withstand voltages are 7 500 / 10 000 / 20 000 V for the SG-10, 17 000 / 20 000 / 30 000 V for the SG-20, 26 500 / 30 000 / 40 000 V for the SG-30 and 36 000 / 40 000 / 50 000 V for the SG-40, with thicknesses below 2.1, 2.9, 3.5 and 4.2 mm respectively. So class 2 is enough in a 10 kV network, while for 35 kV only class 4 remains. Boots and overshoes are made only in classes 1–3, i.e. up to 26.5 kV.

Request a price and lead time

SG / SGM / DB / OB dielectric gloves class 1–4 and dielectric boots and overshoes class 1–3 (7.5–36 kV). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What does category RC mean on dielectric gloves?

RC denotes resistance to acids, oils, ozone and very low temperatures, and gloves of all four classes of the series have it.

How are SG gloves checked for punctures before work?

Integrity is checked with the SG-117 pneumatic tester, which finds punctures by air pressure.

How do DB3 dielectric boots differ from DB2?

The class 3 DB3 are rated for 26.5 kV (proof test 30 kV), are lightweight, flexible down to −40 °C, insulated per EN ISO 20345 and have a shock-absorbing system in the heel. The class 2 DB2 are rated for 17.5 kV.

Can dielectric overshoes be worn over work footwear?

Yes, OB overshoes are made for this. The class 1 OB1 has a vulcanised SRC sole, HRO heat resistance of 300 °C for 60 s and resistance to fuel and oil.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.