Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BATTERY ENERGY STORAGE SYSTEMS (BESS)

Center F — 20/40 ft BESS Containers

Center F is produced as a containerized energy storage system on lithium iron phosphate batteries in 20 and 40 ft formats. It is supplied fully assembled and tested at the factory on a plug-and-play basis.

Design
20 ft; 40 ft; 40 ft without internal aisle (non-walk-in)
DC voltage
1500 V (20 ft, 40 ft non-walk-in); 1000 V (40 ft)
Chemistry
lithium iron phosphate
Seismic rating
zone 4

Technical specifications

Design20 ft; 40 ft; 40 ft without internal aisle (non-walk-in)
DC voltage1500 V (20 ft, 40 ft non-walk-in); 1000 V (40 ft)
Chemistrylithium iron phosphate
Seismic ratingzone 4
CertificationUL 9540, UL 9540A, NFPA

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Full factory assembly and testing reduce on-site work to installation and connection. There are three versions, namely 20 ft, 40 ft and 40 ft without an internal aisle (non-walk-in). The DC voltage is 1500 V for the 20 ft and 40 ft non-walk-in versions, and 1000 V for the standard 40 ft container. This determines which converter it can be connected to and with what scheme, so the voltage should be checked at the design stage. Seismic rating is declared for zone 4, which widens the installation geography. Certification covers UL 9540, UL 9540A and NFPA, and the battery chemistry is lithium iron phosphate.

How to choose

First match the DC voltage with the converter. If it is rated for 1500 V, take the 20 ft or the 40 ft non-walk-in, and for 1000 V the 40 ft is suitable. The non-walk-in version has no internal aisle, so servicing is done from outside. For liquid cooling and rack management there are Center L and Center L Plus, and for a ready 6.25 MWh block with a converter, Center L Ultra.

Request a price and lead time

Center F — 20/40 ft BESS Containers. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Which Center F container formats are available?

20 ft, 40 ft and 40 ft without an internal aisle (non-walk-in).

What is the DC voltage of Center F?

1500 V in the 20 ft and 40 ft non-walk-in versions and 1000 V in the standard 40 ft.

What does plug-and-play mean for this container?

The container is fully assembled and tested at the factory, so on site it is only installed and connected.

Which seismic zone is Center F designed for?

The declared seismic rating corresponds to zone 4.

What battery chemistry and certificates does Center F have?

The batteries are lithium iron phosphate. Certification covers UL 9540, UL 9540A and NFPA.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.