Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BATTERY ENERGY STORAGE SYSTEMS (BESS)

WS-L5000 + WS-MV5000 — 5 MW / 5 MWh containerized BESS

A 5 MW / 5 MWh containerized BESS made of the WS-L5000 battery container and the WS-MV5000 power conversion unit. The 20 ft container holds 5,016 kWh, and system efficiency reaches 94.5 %. The set connects straight to the medium-voltage grid, so it belongs at a substation, next to a large PV plant or on a factory site.

Energy
5,016 kWh in a 20 ft container
Application
2/4 hours
Efficiency
up to 94.5 %
Connection (MV5000)
12–36 kV, 50/60 Hz

Technical specifications

Energy5,016 kWh in a 20 ft container
Application2/4 hours
Efficiencyup to 94.5 %
Connection (MV5000)12–36 kV, 50/60 Hz
PCS efficiencyup to 99 %
MV5000 protectionIP54, C5-M
Customs codes (for reference)
HS code8507.60
UKTZED code (Ukraine)8507600000
CN code (EU)85076000

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The batteries in the WS-L5000 are liquid-cooled, which is what lets 5,016 kWh fit into a standard 20 ft footprint without overheating the cells. The WS-MV5000 houses the PCS, rated at up to 99 % efficiency, and the medium-voltage transformer in one unit. No separate transformer kiosk is needed on site, as the cable from the unit runs straight to a 12–36 kV, 50/60 Hz switchgear bay. The gap between 99 % PCS efficiency and 94.5 % system efficiency is taken up by the battery, the transformer and the container auxiliaries, cooling included. The MV5000 enclosure is IP54, and its C5-M corrosion protection is rated for marine and heavily polluted industrial air. The set runs 2-hour or 4-hour discharge applications.

How to choose

Start by deciding which duty the site needs. A two-hour discharge suits peak shaving and ancillary service markets, while four hours suits shifting daytime PV output into the evening. Check your distribution grid voltage against the 12–36 kV range and the transformer version before ordering. When the need is hundreds of kilowatts rather than megawatts, the MC-L522 cabinet with 522.5 kWh and 250 kW or the MC-L430 / MS-L430 with 430.08 kWh and 200 kW makes more sense.

Request a price and lead time

WS-L5000 + WS-MV5000 — 5 MW / 5 MWh containerized BESS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the efficiency of the WS-L5000 + WS-MV5000 BESS?

System efficiency is up to 94.5 %, and PCS efficiency is up to 99 %.

What grid voltage does the WS-MV5000 connect to?

A medium-voltage grid of 12–36 kV at 50/60 Hz.

How much energy is in one WS-L5000 container?

5,016 kWh in a 20 ft liquid-cooled container.

Does the WS-MV5000 need a separate transformer?

No, the medium-voltage transformer is built into the unit together with the PCS. The unit enclosure is IP54 with C5-M protection.

What discharge duration is the WS-L5000 set rated for?

It is rated for 2-hour or 4-hour applications.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.