BATTERY ENERGY STORAGE SYSTEMS (BESS)
Intensium Shift 20-foot BESS container 3 MWh (LFP)
Country: France · Model: Intensium Shift
Energy storage system in a 20-foot container on LFP cells, 3 MWh at C/5 and up to 1.5 MW of DC power. The module is designed for grid and solar-wind sites that need renewables integration, peak coverage and grid support.
- Energy (C/5)
- 3.0 MWh
- Max. DC charge/discharge power
- 1.5 MW
- Voltage range
- 1060–1500 V
- Charge/discharge current
- 1100 A nominal, 1370 A max.
Technical specifications
| Energy (C/5) | 3.0 MWh |
|---|---|
| Max. DC charge/discharge power | 1.5 MW |
| Voltage range | 1060–1500 V |
| Charge/discharge current | 1100 A nominal, 1370 A max. |
| Discharge duration | 2–4 h (2–8 h in parallel operation) |
| Chemistry | LiFePO4 (LFP) |
| Dimensions | 6.1 × 2.4 × 2.9 m (20 ft) |
| Operating temperature | −20…+45 °C |
| Standards | IEC 62619, IEC 62477-1, UL 1973:2022, UL 9540A |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The unit is built on LiFePO4 cells in one container measuring 6.1 × 2.4 × 2.9 m. The operating voltage lies within 1060–1500 V, the nominal charge and discharge current is 1100 A, and the maximum is 1370 A. Discharge lasts 2–4 h, and when several containers operate in parallel the range extends to 2–8 h. The operating temperature is from −20 to +45 °C, so in frost below this limit the container needs separate heating of the site. Control and monitoring are done through the I-Sight platform. The system meets the requirements of IEC 62619, IEC 62477-1 and UL 1973:2022, and has also passed testing under UL 9540A.
How to choose
The main thing here is the ratio of energy to power. The container gives 3.0 MWh at 1.5 MW DC, so a normal cycle lasts 2 h at full power. If longer autonomy is needed, parallel operation extends the discharge to 8 h. For a smaller capacity there is the Intensium Max 20 High Energy at 2300 kWh and a voltage of 1040–1400 V. Systems of 1–50 MW are built from Intensium Max containers. Before choosing, check the 1060–1500 V range against the input voltage window of your PCS.
Request a price and lead time
Intensium Shift 20-foot BESS container 3 MWh (LFP). We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What is the energy capacity of the Intensium Shift container?
3.0 MWh at C/5 in a 20-foot enclosure. The cell chemistry is LiFePO4 (LFP).
What is the maximum DC charge and discharge power?
1.5 MW. Nominal current 1100 A, maximum 1370 A, voltage 1060–1500 V.
For how many hours does the container discharge last?
The discharge duration is 2–4 h. When containers operate in parallel, the range extends to 2–8 h.
What are the container dimensions for site design?
6.1 × 2.4 × 2.9 m, standard 20-foot format. Operating temperature from −20 to +45 °C.
Which standards does the system comply with?
IEC 62619, IEC 62477-1, UL 1973:2022 and testing under UL 9540A.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.