MC Cube-T BESS containerized energy storage system 5.0–6.4 MWh

Grid energy storage system in a 1500 V container, with a capacity from 5010 to 6431 kWh depending on the version. LFP cells, liquid cooling by cluster, compatible with both centralized and string PCS. Designed for power system sites and large PV plants.

Models
MC10C-B5010-E/U-R2, MC12C-B6012-E/U-R2, MC10C-B5365-E/U-R4, MC12C-B6437-E/U-R4
Capacity (DC, FAT)
5010 / 6012 / 5360 / 6431 kWh
Power
2506 / 3006 / 1340 / 1608 kW (0.5C or 0.25C)
Voltage
1331.2 V (range 1081.6–1497.6 V), LFP cells

Technical specifications

ModelsMC10C-B5010-E/U-R2, MC12C-B6012-E/U-R2, MC10C-B5365-E/U-R4, MC12C-B6437-E/U-R4
Capacity (DC, FAT)5010 / 6012 / 5360 / 6431 kWh
Power2506 / 3006 / 1340 / 1608 kW (0.5C or 0.25C)
Voltage1331.2 V (range 1081.6–1497.6 V), LFP cells
Coolingliquid
Protection degreeIP55
Dimensions / weight6058 (7550) × 2438 × 2896 mm / 43.6–53.0 t
Temperature−30…+55 °C
StandardsIEC 62619, UL 9540, UL 9540A, UL 1973, UN 38.3, UN 3536, CE

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The system is assembled from MC Cube-T cubes in one container measuring 6058 (7550) × 2438 × 2896 mm, and the weight depends on the version and is 43.6–53.0 t. The pack voltage is 1331.2 V, the working range is 1081.6–1497.6 V, so the third-party equipment is selected for this window. Liquid cooling is by cluster, the protection degree is IP55, and operating temperatures are from −30 to +55 °C. The R2 versions deliver 2506 and 3006 kW at 0.5C, the R4 versions give 1340 and 1608 kW at 0.25C, that is, a slower discharge in the same form factor. The PCS is supplied separately, and both a centralized and a string type will fit. For acceptance in the project there are the standards IEC 62619, UL 9540, UL 9540A, UL 1973, UN 38.3, UN 3536 and the CE marking.

How to choose

The ratio of capacity to power decides. The models MC10C-B5010 and MC12C-B6012 with index R2 are rated for 0.5C, while MC10C-B5365 and MC12C-B6437 with index R4 are rated for 0.25C, so R2 is taken for fast charge and discharge. If more capacity per container is needed, look at the Haohan at 7284 or 14 568 kWh with protection degree IP66. For a commercial site without a container, the MC Cube cabinets at 501–536 kWh or the Chess Plus at 233 kWh and 125 kW are better.

Request a price and lead time

MC Cube-T BESS containerized energy storage system 5.0–6.4 MWh. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the capacity of the MC Cube-T container?

Depending on the version, 5010, 6012, 5360 or 6431 kWh on the DC side. All models use LFP cells and 1331.2 V.

What is the power of the R2 and R4 versions?

R2 give 2506 kW at 5010 kWh and 3006 kW at 6012 kWh at 0.5C. R4 deliver 1340 and 1608 kW at 0.25C.

What protection degree and temperature range does the MC Cube-T have?

IP55 and operating temperatures from −30 to +55 °C. Cooling is liquid, by cluster.

Which inverter does the MC Cube-T work with?

With centralized and string PCS. The battery voltage range of 1081.6–1497.6 V must be matched with the inverter input window.

What are the weight and dimensions of the container?

Dimensions 6058 (7550) × 2438 × 2896 mm, weight 43.6–53.0 t depending on the version. The foundation is calculated for the heaviest version.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.