OPTIM US …-HY — commercial storage cabinets with a built-in hybrid inverter 104–313 kWh

OPTIM US …-HY outdoor cabinets combine a 104–313 kWh LFP battery with a 50 or 100 kW, 400 V hybrid inverter. They go on commercial sites for peak shaving, shifting consumption to cheaper hours and backup power during outages.

Models
A100-HY M1C (100 kW / 104 kWh), A100-HY M1D (50 kW / 108 kWh), A300-HY (313 kWh), L260-HY
Cells
LFP
AC power
50 / 100 kW, 400 V, 50/60 Hz (A100-HY)
Scaling
up to 5 cabinets, 52–520 kWh, 25–500 kW (M1C)

Technical specifications

ModelsA100-HY M1C (100 kW / 104 kWh), A100-HY M1D (50 kW / 108 kWh), A300-HY (313 kWh), L260-HY
CellsLFP
AC power50 / 100 kW, 400 V, 50/60 Hz (A100-HY)
Scalingup to 5 cabinets, 52–520 kWh, 25–500 kW (M1C)
PV input (M1D)4 MPPT, 150–950 V, up to 100 kW
Grid/off-grid switchover< 10 ms (M1C), 20 ms (M1D)
Protection ratingIP55
Cycle life> 7,000 cycles (M1C, A300-HY)
StandardsIEC 62619, IEC 62040-1, VDE 2510-50, UL 1973, UL 9540A, EN 50549-1, VDE-AR-N 4105
Customs codes (for reference)
HS code8507.60
UKTZED code (Ukraine)8507600000
CN code (EU)85076000

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The A100-HY M1C delivers 100 kW from 104 kWh, a ratio of about 1C for fast peak shaving, while the A100-HY M1D gives 50 kW from 108 kWh and is meant for longer discharge. The M1D has a built-in PV input with 4 MPPT at 150–950 V for up to 100 kW of solar panels, so no separate grid-tie PV inverter is needed. Switchover from grid to island mode takes under 10 ms on the M1C and 20 ms on the M1D, unnoticeable for most loads, much like a UPS. M1C cabinets scale to 5 units, giving a system range of 52–520 kWh and 25–500 kW. The larger A300-HY holds 313 kWh. The IP55 housing is made for an open yard, and the M1C and A300-HY are rated for more than 7,000 cycles.

How to choose

If the task is shaving short peaks, take the M1C with 100 kW. For a site with a rooftop PV plant the M1D fits better, since its PV input is already built in. When more energy in one enclosure is needed, look at the A300-HY with 313 kWh, and for systems from 1 MWh move to OMNI containers, for example the A1000-OMNI with 1,034.88 kWh.

Request a price and lead time

OPTIM US …-HY — commercial storage cabinets with a built-in hybrid inverter 104–313 kWh. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Can solar panels connect directly to the OPTIM A100-HY?

Yes, the M1D version has a PV input with 4 MPPT at 150–950 V for up to 100 kW of panels. No built-in PV input is listed for the M1C.

How fast does an OPTIM cabinet switch to island mode?

On the M1C switchover takes under 10 ms, on the M1D 20 ms. Computers and most drives keep running without a restart.

How far does the OPTIM A100-HY M1C scale?

Up to 5 cabinets operate together, giving 25–500 kW and 52–520 kWh. The grid connection is 400 V, 50/60 Hz.

Which standards are OPTIM US HY cabinets certified to?

The listed standards are IEC 62619, IEC 62040-1, VDE 2510-50, UL 1973, UL 9540A, EN 50549-1 and VDE-AR-N 4105. The last two cover connecting generation to the grid.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.