BATTERY ENERGY STORAGE SYSTEMS (BESS)
OPTIM US …-HY — commercial storage cabinets with a built-in hybrid inverter 104–313 kWh
Country: China · Model: OPTIM US …-HY
OPTIM US …-HY outdoor cabinets combine a 104–313 kWh LFP battery with a 50 or 100 kW, 400 V hybrid inverter. They go on commercial sites for peak shaving, shifting consumption to cheaper hours and backup power during outages.
- Models
- A100-HY M1C (100 kW / 104 kWh), A100-HY M1D (50 kW / 108 kWh), A300-HY (313 kWh), L260-HY
- Cells
- LFP
- AC power
- 50 / 100 kW, 400 V, 50/60 Hz (A100-HY)
- Scaling
- up to 5 cabinets, 52–520 kWh, 25–500 kW (M1C)
Technical specifications
| Models | A100-HY M1C (100 kW / 104 kWh), A100-HY M1D (50 kW / 108 kWh), A300-HY (313 kWh), L260-HY |
|---|---|
| Cells | LFP |
| AC power | 50 / 100 kW, 400 V, 50/60 Hz (A100-HY) |
| Scaling | up to 5 cabinets, 52–520 kWh, 25–500 kW (M1C) |
| PV input (M1D) | 4 MPPT, 150–950 V, up to 100 kW |
| Grid/off-grid switchover | < 10 ms (M1C), 20 ms (M1D) |
| Protection rating | IP55 |
| Cycle life | > 7,000 cycles (M1C, A300-HY) |
| Standards | IEC 62619, IEC 62040-1, VDE 2510-50, UL 1973, UL 9540A, EN 50549-1, VDE-AR-N 4105 |
| Customs codes (for reference) | |
| HS code | 8507.60 |
| UKTZED code (Ukraine) | 8507600000 |
| CN code (EU) | 85076000 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
The A100-HY M1C delivers 100 kW from 104 kWh, a ratio of about 1C for fast peak shaving, while the A100-HY M1D gives 50 kW from 108 kWh and is meant for longer discharge. The M1D has a built-in PV input with 4 MPPT at 150–950 V for up to 100 kW of solar panels, so no separate grid-tie PV inverter is needed. Switchover from grid to island mode takes under 10 ms on the M1C and 20 ms on the M1D, unnoticeable for most loads, much like a UPS. M1C cabinets scale to 5 units, giving a system range of 52–520 kWh and 25–500 kW. The larger A300-HY holds 313 kWh. The IP55 housing is made for an open yard, and the M1C and A300-HY are rated for more than 7,000 cycles.
How to choose
If the task is shaving short peaks, take the M1C with 100 kW. For a site with a rooftop PV plant the M1D fits better, since its PV input is already built in. When more energy in one enclosure is needed, look at the A300-HY with 313 kWh, and for systems from 1 MWh move to OMNI containers, for example the A1000-OMNI with 1,034.88 kWh.
Request a price and lead time
OPTIM US …-HY — commercial storage cabinets with a built-in hybrid inverter 104–313 kWh. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
Can solar panels connect directly to the OPTIM A100-HY?
Yes, the M1D version has a PV input with 4 MPPT at 150–950 V for up to 100 kW of panels. No built-in PV input is listed for the M1C.
How fast does an OPTIM cabinet switch to island mode?
On the M1C switchover takes under 10 ms, on the M1D 20 ms. Computers and most drives keep running without a restart.
How far does the OPTIM A100-HY M1C scale?
Up to 5 cabinets operate together, giving 25–500 kW and 52–520 kWh. The grid connection is 400 V, 50/60 Hz.
Which standards are OPTIM US HY cabinets certified to?
The listed standards are IEC 62619, IEC 62040-1, VDE 2510-50, UL 1973, UL 9540A, EN 50549-1 and VDE-AR-N 4105. The last two cover connecting generation to the grid.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.