Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BATTERY ENERGY STORAGE SYSTEMS (BESS)

PowerBox lithium iron phosphate 512 V battery cabinet for data center UPS

The PowerBox battery cabinet on LFP cells with a nominal voltage of 512 V DC holds 71.68 kWh (140 Ah) and delivers up to 300 kW. It is the manufacturer's first lithium-ion battery system, designed for data center UPS from enterprise to hyperscale.

Chemistry
LFP
Nominal voltage
512 V (432–576 V)
Capacity / energy
140 Ah / 71.68 kWh
Max. discharge power
300 kW per cabinet

Technical specifications

ChemistryLFP
Nominal voltage512 V (432–576 V)
Capacity / energy140 Ah / 71.68 kWh
Max. discharge power300 kW per cabinet
BMSthree-level, RS485/CAN/Ethernet
Ingress protectionIP20
Dimensions, weight600×1000×2050 mm (42U), 1100 kg
Operating temperature0–40 °C

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The operating voltage range of 432–576 V matches the input buses of large three-phase UPS. The modular design allows battery modules to be replaced without shutting down the system, so the data center does not lose its reserve during service. Cell condition is monitored by a three-level BMS with RS485, CAN and Ethernet interfaces, through which the cabinet passes data to the UPS and the monitoring system. The 42U cabinet measures 600×1000×2050 mm and weighs 1100 kg, so the permissible raised-floor load should be checked before installation. The IP20 protection rating and the 0–40 °C range mean installation only in enclosed technical rooms.

How to choose

The number of cabinets is calculated from the UPS power and backup time; one cabinet gives up to 300 kW and 71.68 kWh of energy. Parallel cabinets increase both power and backup time. If the UPS is designed for lead batteries or the budget is limited, pay attention to the manufacturer's lead-acid series for data centers, and for small loads GP monoblocks of 6 and 12 V are suitable.

Request a price and lead time

PowerBox lithium iron phosphate 512 V battery cabinet for data center UPS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

How much energy does the PowerBox battery cabinet hold?

One cabinet holds 71.68 kWh at a capacity of 140 Ah and a nominal voltage of 512 V.

What power does PowerBox deliver to a UPS?

The maximum discharge power is 300 kW per cabinet; for more powerful UPS the cabinets are installed in parallel.

Can a PowerBox module be replaced without switching off the UPS?

Yes, the modular design allows modules to be replaced without stopping the system, so the data center load remains protected.

What interfaces does the BMS of the PowerBox battery cabinet have?

The three-level BMS has RS485, CAN and Ethernet interfaces for communication with the UPS and the monitoring system.

What are the dimensions and weight of the PowerBox cabinet?

The 42U cabinet measures 600×1000×2050 mm and weighs 1100 kg; it operates at 0–40 °C with an IP20 protection rating.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.