DataSafe Noir — lithium-ion storage system for three-phase data center UPS

DataSafe Noir is built from lithium-ion cabinets at 512–614 V DC, each holding 500–600 kW for 5 minutes even at end of life. The system connects to three-phase data center UPS units and scales in modules up to 3 MW.

Chemistry
lithium-ion
DC voltage
512–614 V
Cabinet power
500–600 kW for 5 min (end of life)
Scalability
modular up to 3 MW

Technical specifications

Chemistrylithium-ion
DC voltage512–614 V
Cabinet power500–600 kW for 5 min (end of life)
Scalabilitymodular up to 3 MW
InterfacesCAN, Ethernet, RS485
Safetymulti-level protection at cell, module and system level
Customs codes (for reference)
HS code8507.60
UKTZED code (Ukraine)8507600000
CN code (EU)85076000

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

The high energy density of lithium shrinks the battery room compared with lead racks of the same power. The cabinet power rating is given for end of life, so the degradation margin is already built into the sizing. Variable load, including AI clusters with sharp consumption spikes, is easier on lithium than on lead. Protection works on three levels, separately at cell, module and system. Communication with the UPS and monitoring runs over CAN, Ethernet and RS485, so battery status shows up in the building control room. The 512–614 V window is matched to the DC input of the specific UPS, and compatibility is checked before ordering.

How to choose

The cabinet count follows from UPS power and required runtime, and at 5 minutes one cabinet covers 500–600 kW. Halls up to 3 MW grow by adding modules without replacing installed cabinets. If the UPS is set up for lead, the alternatives are DataSafe XE TPPL blocks for discharges under 5 minutes or flooded DataSafe DX at 300–1,915 Ah.

Request a price and lead time

DataSafe Noir — lithium-ion storage system for three-phase data center UPS. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What DC voltage does DataSafe Noir use?

The operating window is 512–614 V. It must match the permitted DC input of the three-phase UPS.

How much power does one DataSafe Noir cabinet hold?

A cabinet delivers 500–600 kW for 5 minutes, and that figure is rated at end of life.

How far does DataSafe Noir scale?

It scales in modules up to 3 MW, with cabinets added as data center load grows.

What communication interfaces does DataSafe Noir have?

CAN, Ethernet and RS485. Through them the battery exchanges data with the UPS and the monitoring system.

Is DataSafe Noir suitable for AI workloads?

Yes, it is built for data centers with variable load, AI clusters with sharp consumption spikes included.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.