Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BATTERY ENERGY STORAGE SYSTEMS (BESS)

Rack for Gemini / Taurus — rack energy storage system for a high voltage cabin, from 75 kWh

This version of the rack BESS from 75 kWh is mounted in the free volume of a Gemini or Taurus type high voltage cabin, with a 20, 30 or 60 kW inverter included. No separate room is needed for the storage unit, and cable routes from the battery to the entry are minimal.

Capacity
from 75 kWh
Inverter power
20 / 30 / 60 kW
Installation
inside a Gemini / Taurus high voltage cabin, minimum of cable connections
Access
controlled access to the battery

Technical specifications

Capacityfrom 75 kWh
Inverter power20 / 30 / 60 kW
Installationinside a Gemini / Taurus high voltage cabin, minimum of cable connections
Accesscontrolled access to the battery
Inverterincluded

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The storage unit stands next to the high voltage entry equipment, so cable connections are kept to a minimum and the cost of cable and installation is reduced. Access to the battery is controlled, which matters in a cabin that only electrical personnel may enter. By design this is the same rack system as the Indoor rack, adapted for installation in a cabin. The in-house BMS IQ controls the battery and exchanges data with any EMS, so a cabin storage unit is easy to include in the overall energy management system. Fire suppression, as in the other systems of the range, is provided at module level. Typical tasks of such a storage unit are peak shaving and operating a site when the connection capacity is limited. The battery modules for it are assembled in Belgium.

How to choose

The first thing to check is whether a Gemini or Taurus cabin has free volume for a rack. Then choose a 20, 30 or 60 kW inverter by the power the storage unit must deliver to the site grid. If the cabin is of another type or there is not enough room in it, the Indoor rack for a technical room with a 50 by 90 cm rack or the outdoor cabinet from 261 kWh with 125 kW is more suitable.

Request a price and lead time

Rack for Gemini / Taurus — rack energy storage system for a high voltage cabin, from 75 kWh. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Can a storage battery be installed in a high voltage cabin?

Yes, this version is designed for Gemini or Taurus type cabins. The rack is placed in the free volume of the cabin, and access to the battery is controlled.

What is the minimum capacity of the rack BESS for a Gemini / Taurus cabin?

The system starts from 75 kWh, and the included inverter has a power of 20, 30 or 60 kW.

Why put an energy storage unit in a cabin rather than in a separate room?

This shortens cable routes and reduces the number of connections, and no separate room or pad for the BESS is needed.

How does the Rack for Gemini / Taurus differ from the Indoor rack?

The capacity from 75 kWh and the 20, 30 or 60 kW inverters are the same. The Indoor rack is placed in a technical room or basement, while this version is mounted inside a cabin.

How is fire protection of the storage unit in a cabin organised?

Fire suppression is provided at module level, and controlled access keeps unauthorised people away from the battery section.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.