BATTERY ENERGY STORAGE SYSTEMS (BESS)
OptiGrid — turnkey grid energy storage systems
Country: USA · Model: OptiGrid
The OptiGrid energy storage system is delivered turnkey on TPPL batteries whose cells deliver 292–4,094 W over a 15-minute discharge. It targets utilities and industrial consumers that need grid stabilization, peak shaving and power capping.
- Battery technology
- TPPL
- Cell power
- 292–4,094 W/cell (15 min)
- Scope
- batteries, power conversion system, monitoring, enclosure
- Application
- front of the meter (grid) and behind the meter: peak shaving, demand management
Technical specifications
| Battery technology | TPPL |
|---|---|
| Cell power | 292–4,094 W/cell (15 min) |
| Scope | batteries, power conversion system, monitoring, enclosure |
| Application | front of the meter (grid) and behind the meter: peak shaving, demand management |
| Customs codes (for reference) | |
| HS code | 8507.20 |
| UKTZED code (Ukraine) | 8507208090 |
| CN code (EU) | 85072080 |
Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.
Description
The scope covers batteries, a power conversion system (PCS), monitoring and an enclosure, so the customer gets a finished installation rather than a set of racks. TPPL cells with thin pure lead plates take short heavy discharges well, and those are what grid support and peak shaving demand. In front of the meter the system works for the grid and helps the utility relieve congested nodes. Behind the meter it sits at an industrial site, clips consumption peaks and cuts demand charges. Monitoring is part of the delivery, so battery status is visible without a separate data acquisition system. The enclosure with batteries and converter is placed on a substation pad or next to a plant building.
How to choose
Sizing starts from the load profile, first the required power and discharge duration, then the number of cells rated 292–4,094 W/cell. For UPS backup in data centers the lithium option is DataSafe Noir with 500–600 kW cabinets scaling to 3 MW. If only a battery array without PCS is needed, build it from DataSafe XE or Genesis EP TPPL blocks.
Request a price and lead time
OptiGrid — turnkey grid energy storage systems. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What does the OptiGrid storage system include?
TPPL batteries, a power conversion system, monitoring and an enclosure. The customer gets a turnkey installation.
Is OptiGrid used in front of or behind the meter?
Both. In front of the meter it supports the grid, and behind the meter it clips consumption peaks and manages plant demand.
How much power do OptiGrid cells deliver?
Each TPPL cell gives 292–4,094 W at a 15-minute discharge. Total system power depends on cell count and the converter.
Why does OptiGrid use lead batteries instead of lithium?
TPPL cells handle short heavy discharges and long float periods well, and substation staff already know how to service them.
Who is OptiGrid for?
Utilities that need grid stabilization and industrial users that want to cut peaks and cap their power draw.