Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BATTERY ENERGY STORAGE SYSTEMS (BESS)

RW-F10.2 / RW-F10.2-B / RW-F16 — 48 V 10.2–16 kWh wall-mounted batteries

RW-F wall-mount LiFePO4 batteries at 51.2 V come in two sizes, the RW-F10.2 stores 10.24 kWh (200 Ah) and the RW-F16 is rated 314 Ah with 14.4 kWh of usable energy. They hang next to a hybrid inverter in a private house. Up to 32 batteries connect in parallel for 326 kWh.

Chemistry
LiFePO4
Voltage
51.2 V
Energy
10.24 kWh (200 Ah), RW-F16: 314 Ah (14.4 kWh usable)
Current
up to 240 A (F10.2), 160 A (F16)

Technical specifications

ChemistryLiFePO4
Voltage51.2 V
Energy10.24 kWh (200 Ah), RW-F16: 314 Ah (14.4 kWh usable)
Currentup to 240 A (F10.2), 160 A (F16)
Scalabilityup to 32 units in parallel (326 kWh)
Cycle life≥ 6,000 cycles
Ingress protectionIP20; RW-F10.2-B: NEMA 3R (IP65)
Customs codes (for reference)
HS code8507.60
UKTZED code (Ukraine)8507600000
CN code (EU)85076000

Specifications are taken from the manufacturer’s technical documentation. Updated . Customs codes are for reference only; the final code is determined at customs declaration for the specific model.

Description

Both models have a nominal 51.2 V, which is the 48 V battery class. Discharge current reaches 240 A on the F10.2 and 160 A on the F16, so the smaller model carries a heavier load despite storing less energy. At 240 A the cable to the inverter and the breaker are sized for the battery's full current, not for the average household load. Cycle life is at least 6,000 cycles. The base enclosure is IP20, so these batteries hang indoors on a wall strong enough for their weight. The RW-F10.2-B is built for the US market with NEMA 3R (IP65) protection and can be mounted outside.

How to choose

The choice here comes down to energy versus current. The RW-F16 gives more overnight reserve with 14.4 kWh usable but is limited to 160 A, while the RW-F10.2 stores 10.24 kWh and handles up to 240 A for an inverter with heavy starting loads. For an exterior wall the RW-F10.2-B with NEMA 3R fits, and the SE-F12 Max and SE-F16 Max are also made for outdoors with IP65 and a heated -H version. If battery and inverter should come as one wall unit, the RW-F5.1-1H2 at 5,000 W is closer.

Request a price and lead time

RW-F10.2 / RW-F10.2-B / RW-F16 — 48 V 10.2–16 kWh wall-mounted batteries. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What discharge current do the RW-F10.2 and RW-F16 deliver?

Up to 240 A on the RW-F10.2 and up to 160 A on the RW-F16.

How many RW-F batteries can connect in parallel?

Up to 32 units, up to 326 kWh in total.

How does the RW-F10.2-B differ from the RW-F10.2?

It is the US-market version with a NEMA 3R (IP65) enclosure instead of IP20, so it can go outside.

How much usable energy does the RW-F16 have?

14.4 kWh from 314 Ah at 51.2 V.

What cycle life do RW-F batteries have?

At least 6,000 cycles on both models.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.