Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BURNERS AND GAS VALVES

WGL30–WGL40 compact dual-fuel gas/oil burners 70–550 kW

The compact WGL30–WGL40 dual-fuel burners of 70–550 kW burn gas or liquid fuel and switch to the standby fuel when the gas supply is interrupted. They are installed where heat supply must be guaranteed, i.e. in boiler rooms of public and industrial buildings, hospitals and food industry plants.

Types
WGL30/1 – 70–340 kW; WGL40/1 – 125–550 kW
Gas
natural gas E, LL, liquefied gas B/P; up to 20 vol. % hydrogen
Liquid fuel
heating oil EL and low-sulphur EL (DIN 51603-1), EL A Bio up to 20.9 % (option up to 30.9 %), paraffinic EL P (DIN/TS 51603-8)
Fuel changeover
including remotely via a fieldbus module

Technical specifications

TypesWGL30/1 – 70–340 kW; WGL40/1 – 125–550 kW
Gasnatural gas E, LL, liquefied gas B/P; up to 20 vol. % hydrogen
Liquid fuelheating oil EL and low-sulphur EL (DIN 51603-1), EL A Bio up to 20.9 % (option up to 30.9 %), paraffinic EL P (DIN/TS 51603-8)
Fuel changeoverincluding remotely via a fieldbus module
Fuel pumpwith a separate motor, switched off during gas operation
Air damperelectronically controlled, closes during shutdown
Controldigital combustion manager, expansion modules, O2 trim (option)

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

In normal operation the burner runs mainly on gas, and switching to liquid fuel, including so-called Green Fuels, can also be done remotely via a fieldbus module. The series belongs to the W burner family and adds fuel flexibility to it. The fuel pump has a separate motor and is switched off on gas, which protects the pump and reduces power consumption. The electronically controlled air damper closes during shutdown, so the furnace does not cool down. The new mixing system works at low gas connection pressure, so the gas train can have a smaller diameter. The air intake housing is sound-damped, and the combustion manager with an integrated connector console and coded numbered plugs simplifies installation and service. The digital manager delivers exactly the amount of heat the boiler requires and, through digital communication, allows the burner to be monitored, set up and diagnosed and to be included in the building automation system.

How to choose

The size is determined by the boiler output. For a boiler up to 125 kW only the WGL30/1 with a range of 70–340 kW is suitable, above 340 kW only the WGL40/1 at 125–550 kW, and between these values the power reserve decides. Expansion modules with analogue inputs and outputs, bus communication modules and O2 trim with an external module and probe can be ordered as options. If standby fuel is not needed, look at the gas WM-G monarch at 55–12 000 kW, and for boilers of 1100–17 000 kW the monobloc WKmono-G/GL 80.

Request a price and lead time

WGL30–WGL40 compact dual-fuel gas/oil burners 70–550 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

Does the WGL burner run on gas with hydrogen?

Yes, for natural gas of groups E and LL and liquefied gas B/P a hydrogen share of up to 20 % by volume is permitted.

Which liquid fuel can be burned in WGL30/1 and WGL40/1?

Heating oil EL and low-sulphur EL per DIN 51603-1, EL A Bio with bio components up to 20.9 % (optionally up to 30.9 %) and paraffinic heating oil EL P per DIN/TS 51603-8.

Can WGL be switched from gas to liquid fuel remotely?

Yes, switching is done through a fieldbus module, and the same digital link is used for diagnostics and connection to building automation.

Why does the WGL burner have a separate fuel pump motor?

During gas operation the pump is switched off, so it does not wear running idle and does not use electricity.

Similar products

Burners and gas valves

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.