GBC, GBS, GBS-H, LANCEFIRE gas burners for industrial furnaces, 15–5000 kW
Country: Germany · Model: GBC / GBS / GBS-H / LANCEFIRE
The GBC, GBS, GBS-H and LANCEFIRE gas burner range covers an output from 15 to 5000 kW and is made for industrial furnaces and process plants with medium and high process temperatures. Typical applications are multi-burner systems with pulse or zone modulating control in the ceramics, metallurgy and machine building industries, and heat treatment and heating furnaces.
- Output
- 15–5000 kW (GBC/GBS); GBS-H 750–5000 kW
- GBC
- ceramic flame nozzle, high exit velocity, for furnaces with fibre lining and pulse control; GBC 50–200
- GBS
- metal nozzle or operation with a burner block
- GBS-H
- low air pressure, processes up to 1600 °C, combustion air up to 500 °C, pilot burner and UV monitoring
Technical specifications
| Output | 15–5000 kW (GBC/GBS); GBS-H 750–5000 kW |
|---|---|
| GBC | ceramic flame nozzle, high exit velocity, for furnaces with fibre lining and pulse control; GBC 50–200 |
| GBS | metal nozzle or operation with a burner block |
| GBS-H | low air pressure, processes up to 1600 °C, combustion air up to 500 °C, pilot burner and UV monitoring |
| LANCEFIRE | high-velocity nozzle-mix burner for tunnel kilns |
| Ignition / monitoring | direct electric ignition; ionisation electrode, UV sensor |
| Fuel | natural gas and other industrial gases; GBS-H also gas/liquid fuel |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
From 2026 the developer of these burners is part of the group of a manufacturer of gas valves and combustion controls. The basic GBC/GBS series has a wide turndown range, direct electric ignition and flame monitoring with an ionisation electrode, or a UV sensor to order. Exit velocity, flame shape and length are set by the choice of burner head and burner block contour. The GBC is fitted with a ceramic flame nozzle with various outlet diameters, and the variable housing length is adjusted to the furnace wall thickness. The GBS has a metal nozzle, so it is used for low and medium temperatures or mounted together with a refractory burner block. The high-temperature GBS-H is made for low air pressure, is lit from a pilot burner and has UV flame monitoring in all sizes. It has a conically widened block for a long soft flame and a narrowed one for a short turbulent flame, and gas/oil versions exist. The burners run on natural gas and other clean industrial gases.
How to choose
The deciding parameters are process temperature and lining type. For fibre lining with pulse control the GBC in sizes 50–200 is used, the GBS suits low and medium temperatures, and processes up to 1600 °C with combustion air up to 500 °C require the GBS-H at 750–5000 kW. If flue gas heat has to be returned to the combustion air, look at the recuperative RECUFIRE at 15–300 kW or the regenerative REGFIRE pairs at 400–1900 kW. For dryers and afterburning there is the CONEFIRE GB at 125–4000 kW.
Request a price and lead time
GBC, GBS, GBS-H, LANCEFIRE gas burners for industrial furnaces, 15–5000 kW. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What output do the GBC and GBS burners have?
The GBC/GBS series covers the range from 15 to 5000 kW, and the exact output is set by the size. The high-temperature GBS-H is made for 750–5000 kW.
Up to what process temperature does the GBS-H burner work?
With a burner block the GBS-H is used on plants with a process temperature up to 1600 °C, and the combustion air can be up to 500 °C.
Which burner is installed in a brick firing kiln?
The high-velocity GBC 80 with a ceramic nozzle is used for such kilns. In tunnel kilns the LANCEFIRE with nozzle mixing also works.
Is flame monitoring needed for LANCEFIRE?
No, the LANCEFIRE works without flame monitoring. The GBC and GBS are monitored with an ionisation electrode or a UV sensor, the GBS-H always with a UV sensor.
Similar products
Selectra M/MRSelectra electronic gas flame modulation systems: M/MR valves (3.4 kPa inlet), amplifiers, sensors, controllers
WGL30/1, WGL40/1WGL30–WGL40 compact dual-fuel gas/oil burners 70–550 kW
LasGAR Basic / LasGAR PlusLasGAR Basic / LasGAR Plus piezo proportional cutting gas pressure regulators for laser cutting machines, input up to 40 bar, output 0.1–30 bar
RV52–RV111RV52–RV111 (Straight-Thru-Flow) direct-acting gas pressure regulators Rp 1/2–Rp 3, inlet up to 20 kPaREQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.