Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BURNERS AND GAS VALVES

WKmono-G/GL 80 — industrial monoblock gas and dual-fuel burners 1100–17 000 kW

WKmono-G/GL 80 industrial monoblock gas and dual-fuel burners for 1100–17 000 kW with the fan in the housing. Burner length is 1630 mm, and the mixing system is taken from the WK duoblock series.

Output
1100–17 000 kW
Burner length
1630 mm
Gas
WKmono-G80/1 and G80/2: NR 1200–17 000; 3LN 1100–17 000; 4LN 1300–16 000; swirlflame 2200–17 000 kW
Dual-fuel
WKmono-GL80/1 and GL80/2: NR 1200–17 000; 3LN 1200–16 000; 4LN 1300–16 000 kW

Technical specifications

Output1100–17 000 kW
Burner length1630 mm
GasWKmono-G80/1 and G80/2: NR 1200–17 000; 3LN 1100–17 000; 4LN 1300–16 000; swirlflame 2200–17 000 kW
Dual-fuelWKmono-GL80/1 and GL80/2: NR 1200–17 000; 3LN 1200–16 000; 4LN 1300–16 000 kW
Mixing systemfrom the WK series; slides out to the service position inside the housing; removal through the housing up to 700 mm
Fuelgas (up to 20 vol. % H2, with individual acceptance); EL, EL A Bio up to 99.9 %, FAME, EL P
Controldigital combustion manager, integration into automation systems

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The burners for steam and hot water boilers, boilers of CHP plants and boiler houses, and process heat generators are made for gas, liquid fuel and in dual-fuel versions. Gas 4LN multiflam ARF come in versions G80/1 (1300–13 000 kW) and G80/2 (1600–16 000 kW), 3LN multiflam G80/1 (1100–13 000) and G80/2 (1600–17 000), NR G80/1 (1200–13 000) and G80/2 (2200–17 000), swirlflame for very short furnaces G80/2 (2200–17 000 kW). Dual-fuel 4LN are GL80/1 (1300–13 000) and GL80/2 (1600–16 000), 3LN GL80/1 (1200–13 000) and GL80/2 (1600–16 000), NR GL80/1 (1200–13 000) and GL80/2 (2200–17 000 kW). Multiflam with internal flue gas recirculation gives the NOx level of compact burners, 4LN has built-in recirculation, and the W-FM 200 manager stabilises the flame. The mixing system slides out to the service position inside the housing, and mixing devices up to 700 mm long are removed through the housing. The digital combustion manager is standard, controls operation on gas and liquid fuel and connects to automation systems. For most burners up to 20 % hydrogen in natural gas is allowed; liquid fuel EL, EL A Bio up to 99.9 %, FAME, EL P.

How to choose

The type is chosen by output and furnace. For 17 000 kW, G80/2 in 3LN, NR and swirlflame versions are suitable, while 4LN with built-in recirculation is limited to 16 000 kW. If the fan must be placed apart from the burner, the WK duoblock series up to 32 000 kW is considered, and for lower outputs WM-G monarch at 55–12 000 kW.

Request a price and lead time

WKmono-G/GL 80 — industrial monoblock gas and dual-fuel burners 1100–17 000 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What are the length and output of WKmono 80 burners?

Burner length is 1630 mm, output from 1100 to 17 000 kW.

What fuels does WKmono 80 run on?

On gas, liquid fuel EL, EL A Bio up to 99.9 %, FAME and EL P, and in the dual-fuel version.

Is hydrogen in the gas allowed?

Up to 20 % hydrogen in natural gas for most burners, with individual acceptance.

How is the mixing system serviced?

It is slid out to the service position inside the housing, and devices up to 700 mm long are removed through the housing.

Similar products

Burners and gas valves

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.