Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BURNERS AND GAS VALVES

HeatEngine modular premix system with a point burner head for natural gas and H2, 25–140 kW

A modular system with full premixing of gas and air and a point burner head, 25–140 kW on natural gas and 25–70 kW on hydrogen. The turndown ratio is up to 1:10 and the process temperature up to 450 °C. It is used in drying and furnace installations of the food industry, in laundry equipment and in air heating chambers.

NG power
25, 40, 65, 90, 140 kW
H2 power
25, 40, 70 kW (burner with flame arrester)
Burner diameter
NG 40, 60, 70, 98, 130 mm; H2 40, 60, 98 mm
Turndown range
up to 1:10

Technical specifications

NG power25, 40, 65, 90, 140 kW
H2 power25, 40, 70 kW (burner with flame arrester)
Burner diameterNG 40, 60, 70, 98, 130 mm; H2 40, 60, 98 mm
Turndown rangeup to 1:10
ModulesM1 gas connection, M2 gas line (EN ISO 13577-2), M3 fan and mixer, M4 transition, M5 burner head, M6 burner control unit, M7 electrical installation
Power supply230 or 110 V AC
Gas inlet pressure30 mbar or 65 mbar (depending on version)
Process temperatureup to 450 °C

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The system is assembled from seven modules M1–M7 for a specific process and is supplied ready for connection. M1 includes the gas connection with a ball valve and a flexible hose of 0.5 or 1.0 m, and M2 is the gas line per EN ISO 13577-2 with a pressure gauge. M3 combines the fan and mixer at 230 or 110 V AC, with a power of 25, 40, 65, 90 or 140 kW for natural gas and 25, 40 or 70 kW for hydrogen. M4 provides the transition to the burner, straight (100 mm) or with a 90° turn, and a pressure switch. M5 is a point head with a diameter of 40, 60, 70, 98 or 130 mm, and for hydrogen 40, 60 or 98 mm with a flame arrester. M6 controls combustion in a metal or plastic housing at 230 or 110 V, and M7 is the electrical installation. The gas inlet pressure is 30 or 65 mbar depending on the version, and the ambient temperature is from −15 to +60 °C.

How to choose

The power is set by module M3 and the diameter of head M5. For natural gas there are five steps from 25 to 140 kW, for hydrogen three from 25 to 70 kW, and the hydrogen head has a flame arrester and runs on 100 % H2. If a power above 140 kW or a more flexible choice of fuel is needed, look at the CONEFIRE GB process burners of 125–4000 kW.

Request a price and lead time

HeatEngine modular premix system with a point burner head for natural gas and H2, 25–140 kW. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What powers are available for natural gas and hydrogen?

For natural gas 25, 40, 65, 90 or 140 kW, for hydrogen 25, 40 or 70 kW. The turndown ratio is up to 1:10.

Can the system run on 100 % hydrogen?

Yes, there is a hydrogen version with a 40, 60 or 98 mm head and a built-in flame arrester.

What are the supply voltage and gas inlet pressure?

The fan and burner control unit work from 230 or 110 V AC. The gas inlet pressure is 30 mbar or 65 mbar depending on the version.

What temperature does the system work up to?

The process temperature is up to 450 °C at an ambient temperature from −15 to +60 °C.

Similar products

Burners and gas valves

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.