Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

BURNERS AND GAS VALVES

CONEFIRE and GRIDFIRE multi-fuel process burners and duct burners for drying and afterburning

Process burners for heating air in dryers, cleaning exhaust air and thermal afterburning. CONEFIRE GB gives 125–4000 kW in ten sizes GB0–GB9 on gas, liquid fuel or a combination of them, with a process temperature up to 900 °C. The GRIDFIRE duct burner is assembled from segments of up to 240 kW.

CONEFIRE GB
125–4000 kW; gas, liquid fuel or combined; 10 sizes (GB0–GB9)
Turndown range
gas up to 1:50, liquid fuel up to 1:8–1:10, air over 1:10
Max. process temperature
900 °C
CONEFIRE HT
built-in burners for thermal afterburning, combustion in contaminated air without a fan

Technical specifications

CONEFIRE GB125–4000 kW; gas, liquid fuel or combined; 10 sizes (GB0–GB9)
Turndown rangegas up to 1:50, liquid fuel up to 1:8–1:10, air over 1:10
Max. process temperature900 °C
CONEFIRE HTbuilt-in burners for thermal afterburning, combustion in contaminated air without a fan
CONEFIRE G-Spspecial gas version (manufacturer page)
GRIDFIREmodular segments I, T, X up to 240–280 kW; inlet air up to 400 °C; gas pressure ~60 mbar (NG), ~70 mbar (LPG)
ROTAFIRElinear burner 125 kW per module, excess air 20–40 %, turndown 1:10
Flame monitoringUV sensor, ionization

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

CONEFIRE GB has a radially symmetrical mixing cone and staged air supply, with turndown of up to 1:50 on gas, up to 1:8–1:10 on liquid fuel and over 1:10 on air. Interchangeable fuel lances are designed for one or two gases, one or two liquid fuels, gas-oil combined firing and special fuels. For liquid fuel and for gas burners above the fourth size there is a built-in gas pilot burner, and high-energy ignition is also possible. The flame is monitored by a UV cell or ionization. CONEFIRE HT is built into afterburning installations and burns contaminated exhaust air, so a combustion air fan is not needed. GRIDFIRE consists of base elements I, T and X, the segment power is 240–280 kW, the inlet air temperature of a standard module is up to 400 °C, and the gas pressure is about 60 mbar for natural gas and 70 mbar for LPG. ROTAFIRE gives 125 kW per module for installation in the roof of a process air duct.

How to choose

The burner type is determined by the shape and size of the installation. For a chamber or dryer of high power where deep turndown is needed, CONEFIRE GB with a lance for the given fuel is used. For heating air in a duct GRIDFIRE is suitable, and the number of I, T and X segments is selected for the cross-section. If a power up to 140 kW with premixing or a hydrogen version is needed, look at HeatEngine.

Request a price and lead time

CONEFIRE and GRIDFIRE multi-fuel process burners and duct burners for drying and afterburning. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power of CONEFIRE GB?

125–4000 kW in ten sizes GB0–GB9, with a process temperature up to 900 °C.

What turndown range do the burners have?

Up to 1:50 on gas, up to 1:8–1:10 on liquid fuel, over 1:10 on air.

What fuels does CONEFIRE GB run on?

On gas, liquid fuel or a combination, including gas-oil combined firing and special gases. Interchangeable lances are designed for one or two types of fuel.

What gas pressure does GRIDFIRE need?

About 60 mbar for natural gas and 70 mbar for LPG; a segment gives 240–280 kW.

Similar products

Burners and gas valves

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.