А561 — inductosyn-to-encoder signal converter
Country: Ukraine · Model: А561
1–1000 periods per winding pitch · TTL (5 V) or HTL (10–27 V) outputs · supply 18–27 V AC or 20–30 V DC · 49–61 Hz
The А561 is an electronic interface module that accepts inductosyn signals and outputs standard encoder signals. It works with the ПИЛП1-А2 linear displacement transducer or any sensor with similar characteristics. The converter generates square-wave quadrature differential SIN and COS signals at TTL or HTL levels. The number of output periods per pitch of the inductosyn's printed winding is specified when ordering, anywhere from 1 to 1000. A reference mark signal (SR) is also produced, with a duration of one quarter of the SIN/COS period. An error signal is issued if the connection to the sensor is lost. The unit can be powered from an AC supply of 18–27 V at 49–61 Hz or from a DC supply of 20–30 V. The output stage takes its power from an external source. Weight is no more than 0.6 kg. Typical applications include connecting inductosyns to CNC systems and digital readout devices on machine tools.
- Input signal
- inductosyn ПИЛП1-А2 or equivalent
- Output signals
- SIN, COS (square-wave quadrature differential), SR
- Output signal levels
- TTL or HTL (specified when ordering)
- SIN/COS periods per winding pitch
- 1–1000 (specified when ordering)
Technical specifications
| Input signal | inductosyn ПИЛП1-А2 or equivalent |
|---|---|
| Output signals | SIN, COS (square-wave quadrature differential), SR |
| Output signal levels | TTL or HTL (specified when ordering) |
| SIN/COS periods per winding pitch | 1–1000 (specified when ordering) |
| SR signal duration | 1/4 of SIN/COS period |
| Error signal | on loss of connection to inductosyn |
| AC supply voltage | 18–27 V |
| Supply frequency | 49–61 Hz |
| DC supply voltage | 20–30 V |
| Output stage supply (TTL) | 5 V, external source |
| Output stage supply (HTL) | 10–27 V, external source |
| Weight | max. 0.6 kg |
| Dimensions | max. 205 × 115 × 46 mm |
| Options | cable connectors or cables of specified length |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Choose the output level to suit the input of the CNC system or digital readout. TTL operation needs an external 5 V supply for the output stage, while HTL operation needs a 10–27 V supply. Specify the number of periods per winding pitch, from 1 to 1000, at the time of ordering to obtain the required resolution. Connectors or ready-made cables of a specified length can be ordered separately.
Similar products
Request a price and lead time
А561 — inductosyn-to-encoder signal converter. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.