А570 — current monitoring relay with OVERLOAD and READY outputs

rated current 5–50 A · frequency 0–50 Hz · supply (24 ± 4) V · isolation up to 4 kV

The А570 is a current monitoring relay that measures the RMS value of current in the monitored circuit and provides two discrete signals. The OVERLOAD signal is generated when the current leaves the thresholds set by the operator, while the READY signal confirms that the relay is in its operating state. Versions are available for rated currents of 5, 10, 20, 30 and 50 A, with an input current frequency range of 0 to 50 Hz. The relay is powered from (24 ± 4) V, and the supply and input circuits are separated by galvanic isolation of at least 1 kV. The output relays switch external circuits of 5–250 V AC and up to 30 V DC. Their isolation from the measured signal is 4 kV for the overload channel and 3 kV for the ready channel. The compact 90x35x64 mm housing weighs 0.1 kg and fits easily into control cabinets. Typical uses are current monitoring in industrial electrical installations and overload signalling in equipment protection systems.

Rated measured current
5, 10, 20, 30, 50 A
Input current frequency
0 to 50 Hz
Supply voltage
(24 ± 4) V
Galvanic isolation, supply – input
at least 1 kV

Technical specifications

Rated measured current5, 10, 20, 30, 50 A
Input current frequency0 to 50 Hz
Supply voltage(24 ± 4) V
Galvanic isolation, supply – inputat least 1 kV
OVERLOAD output: switched voltage5–250 V AC, up to 30 V DC
OVERLOAD output: switched current0.01–6 A
OVERLOAD output: isolation from measured signal4 kV
READY output: switched voltage5–250 V AC, up to 30 V DC
READY output: switched current0.001–5 A
READY output: isolation from measured signal3 kV
Continuous operating timeat least 16 h
Overall dimensionsmax. 90x35x64 mm
Weightmax. 0.1 kg

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

Select the version by the rated current of the monitored circuit: 5, 10, 20, 30 or 50 A. The rating should cover the working load current. Also check the output loads. The OVERLOAD contact switches 0.01–6 A, while the READY contact switches 0.001–5 A, which makes the second output suitable for low-power signalling circuits.

Similar products

Low-voltage equipment

Request a price and lead time

А570 — current monitoring relay with OVERLOAD and READY outputs. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.