А570 — current monitoring relay with OVERLOAD and READY outputs
Country: Ukraine · Model: А570
rated current 5–50 A · frequency 0–50 Hz · supply (24 ± 4) V · isolation up to 4 kV
The А570 is a current monitoring relay that measures the RMS value of current in the monitored circuit and provides two discrete signals. The OVERLOAD signal is generated when the current leaves the thresholds set by the operator, while the READY signal confirms that the relay is in its operating state. Versions are available for rated currents of 5, 10, 20, 30 and 50 A, with an input current frequency range of 0 to 50 Hz. The relay is powered from (24 ± 4) V, and the supply and input circuits are separated by galvanic isolation of at least 1 kV. The output relays switch external circuits of 5–250 V AC and up to 30 V DC. Their isolation from the measured signal is 4 kV for the overload channel and 3 kV for the ready channel. The compact 90x35x64 mm housing weighs 0.1 kg and fits easily into control cabinets. Typical uses are current monitoring in industrial electrical installations and overload signalling in equipment protection systems.
- Rated measured current
- 5, 10, 20, 30, 50 A
- Input current frequency
- 0 to 50 Hz
- Supply voltage
- (24 ± 4) V
- Galvanic isolation, supply – input
- at least 1 kV
Technical specifications
| Rated measured current | 5, 10, 20, 30, 50 A |
|---|---|
| Input current frequency | 0 to 50 Hz |
| Supply voltage | (24 ± 4) V |
| Galvanic isolation, supply – input | at least 1 kV |
| OVERLOAD output: switched voltage | 5–250 V AC, up to 30 V DC |
| OVERLOAD output: switched current | 0.01–6 A |
| OVERLOAD output: isolation from measured signal | 4 kV |
| READY output: switched voltage | 5–250 V AC, up to 30 V DC |
| READY output: switched current | 0.001–5 A |
| READY output: isolation from measured signal | 3 kV |
| Continuous operating time | at least 16 h |
| Overall dimensions | max. 90x35x64 mm |
| Weight | max. 0.1 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Select the version by the rated current of the monitored circuit: 5, 10, 20, 30 or 50 A. The rating should cover the working load current. Also check the output loads. The OVERLOAD contact switches 0.01–6 A, while the READY contact switches 0.001–5 A, which makes the second output suitable for low-power signalling circuits.
Similar products
Request a price and lead time
А570 — current monitoring relay with OVERLOAD and READY outputs. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.