А572 — current monitoring relay with digital display
Country: Ukraine · Model: А572
20–600 А (with Т-0,66 CT) · 49–61 Hz · 0–20 mA output · (24 ± 4) V supply
The А572 is a current monitoring relay. It monitors the RMS value of AC current through an external current transformer. The relay receives a 0 to 1 V signal from the secondary winding of the loaded transformer. This signal is proportional to the primary current. The current value is shown on a digital display and on a remote analogue indicator. If the current goes outside the set levels, the relay generates two control commands. It also issues a separate readiness command. The output circuits switch 5–250 V AC and 5–30 V DC at currents from 1 mA to 1 A. A 0–20 mA DC analogue output, proportional to the monitored current, is also provided. Two control inputs accept a primary-current switch-on command (for example, motor start) and a blocking command. The supply is (24 ± 4) V and current consumption is no more than 100 mA. The frequency range is 49–61 Hz, and the relay is rated for continuous operation. It is used for motor start monitoring and in interlocking circuits at industrial sites.
- Rated monitored current (with Т-0,66 CT)
- 20, 30, 40, 50, 75, 100, 150, 200, 300, 400, 600 A
- CT secondary signal voltage
- 0 to 1 V
- Monitored current frequency range
- 49–61 Hz
- Switched voltage, AC
- 5–250 V
Technical specifications
| Rated monitored current (with Т-0,66 CT) | 20, 30, 40, 50, 75, 100, 150, 200, 300, 400, 600 A |
|---|---|
| CT secondary signal voltage | 0 to 1 V |
| Monitored current frequency range | 49–61 Hz |
| Switched voltage, AC | 5–250 V |
| Switched voltage, DC | 5–30 V |
| Switched current | 1 mA to 1 A |
| Control input current | max. 10 mA |
| Supply voltage | (24 ± 4) V |
| Current consumption | max. 100 mA |
| Analogue output signal | 0–20 mA DC |
| Inputs and outputs | 2 control inputs, 2 output commands, 1 readiness command |
| Indication | digital and remote analogue |
| Operating mode | continuous |
| Overall dimensions | 53x35x64 mm |
| Weight | 0.1 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
The rated monitored current is set by the current transformer. With a Т-0,66 transformer it is selected from the series 20, 30, 40, 50, 75, 100, 150, 200, 300, 400, 600 А. Choose the value closest to the operating current of the monitored line or motor. For the switched circuits, keep within the limits: up to 250 V AC or 30 V DC, and no more than 1 A.
Similar products
Request a price and lead time
А572 — current monitoring relay with digital display. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.