DW air circuit breakers (ACB) 800–6300 A, up to 150 kA

Air circuit breakers (ACB) rated 800–6300 A in two frame sizes and 11 types, with a breaking capacity up to 150 kA at 440 V. They are installed on the incomers of main switchboards and on sectional and outgoing lines of high power. Each breaker has an electronic trip unit.

Frame sizes
2 frames, 11 types: 800–4000 A and 4000–6300 A
Breaking capacity DW08–DW40
440 V / 65 kA (H1), 440 V / 100 kA (H2)
Breaking capacity DW40b–DW63
440 V / 100 kA (H1), 440 V / 150 kA (H2)
Trip unit
from basic (overcurrent protection) to extended with measurements, programmable functions and communication

Technical specifications

Frame sizes2 frames, 11 types: 800–4000 A and 4000–6300 A
Breaking capacity DW08–DW40440 V / 65 kA (H1), 440 V / 100 kA (H2)
Breaking capacity DW40b–DW63440 V / 100 kA (H1), 440 V / 150 kA (H2)
Trip unitfrom basic (overcurrent protection) to extended with measurements, programmable functions and communication
Protectionslong-time and short-time delay, instantaneous, ground fault, leakage
Measurementscurrent, energy, harmonics; event log, alarms
StandardsIEC 60947-1, IEC 60947-2; tropical version per IEC 60068-2-30

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The first frame covers 800–4000 A, the second 4000–6300 A. The breaking capacity has two levels, H1 for sites with high short-circuit currents or two transformers working in parallel and H2 for heavy industry with very high short-circuit currents. For DW08–DW40 at 440 V this is 65 kA (H1) and 100 kA (H2), for DW40b–DW63 100 kA (H1) and 150 kA (H2) respectively. The draw-out version, selectivity and low maintenance are retained. The electronic unit ranges from a basic version with overcurrent protection to an extended one with measurement and programmable functions. Protections with long-time and short-time delay, instantaneous, ground fault and leakage are available, as well as measurement of current, energy and harmonics. The unit logs events, issues alarms and communicates with a supervisory system, and has navigation buttons and an LCD display. The main terminals can be connected in different ways. The breakers comply with IEC 60947-1 and IEC 60947-2 and have a tropical version.

How to choose

The choice starts with the rated current and the short-circuit current at the installation point. Up to 4000 A the first frame is suitable, above that up to 6300 A the second. The H1 level is appropriate for plants with a high short-circuit current or two parallel transformers, and H2 is needed in heavy industry. Places of use are main switchboards of industrial plants, data centers, buildings, 0.4 kV substations and the auxiliaries of power plants. For lower currents of 32–800 A look at the molded-case G-TWIN.

Request a price and lead time

DW air circuit breakers (ACB) 800–6300 A, up to 150 kA. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the breaking capacity of the DW series ACB?

At 440 V for DW08–DW40 it is 65 kA (H1) and 100 kA (H2), for DW40b–DW63 100 kA (H1) and 150 kA (H2) respectively.

What rated currents does the DW series have?

The series has 11 types in two frame sizes, 800–4000 A and 4000–6300 A.

What protections does the DW electronic unit have?

Long-time and short-time delay, instantaneous protection, ground fault and leakage protection. The extended unit also measures current, energy and harmonics and keeps an event log.

Which standards do the DW breakers meet?

IEC 60947-1 and IEC 60947-2. The tropical version is tested per IEC 60068-2-30.

Do the DW breakers have a draw-out version?

Yes, the draw-out version is retained, together with the selectivity and low maintenance traditional for ACB.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.