TransferPacT transfer switches up to 1600 A
Country: France · Model: TransferPacT
TransferPacT standby supply transfer switches are rated for currents up to 1600 A and voltages up to 690 V in low-voltage networks. The device is supplied as an all-in-one unit with manual, remote or automatic control and works on the incomers of main switchboards, industrial boards and between the mains and a diesel generator.
- Current
- up to 1600 A
- Control
- manual, remote or automatic
- Voltage
- up to 690 V
Technical specifications
| Current | up to 1600 A |
|---|---|
| Control | manual, remote or automatic |
| Voltage | up to 690 V |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
The switch is installed as a ready unit, so the ATS does not have to be assembled on site from two switches, a mechanical interlock and a separate controller. The manual version changes over the feeds with a handle, the remote version executes a command from a control room panel or a building management system, and the automatic version monitors the voltage of the main feed itself and transfers the load to the standby supply. The design does not allow both feeds to be closed at the same time, so the mains and the generator do not end up in parallel. The rated voltage of up to 690 V covers both ordinary three-phase building networks and 690 V industrial networks with powerful motors. The 1600 A limit makes it possible to install the switch right on the main incomer of a switchboard. Switching is mechanical, so the interruption in supply equals the contact travel time, and for lighting, pumps or ventilation it is acceptable.
How to choose
First of all look at the incomer current and the network voltage, which must fit within 1600 A and 690 V. The control method depends on how the site operates. Manual suits rare planned changeovers, remote suits buildings with supervisory control, and automatic suits backup from a generator or a second line without staff on duty. If the load cannot tolerate even a short break, static STS switches with a transfer time of less than 4 ms are installed instead of a mechanical device.
Request a price and lead time
TransferPacT transfer switches up to 1600 A. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
FAQ
What current and voltage are the TransferPacT switches rated for?
The range covers currents up to 1600 A and voltages up to 690 V. This is enough for the main incomers of building main switchboards and workshop boards.
What control modes does the TransferPacT transfer switch have?
There is manual, remote and automatic control. In automatic mode the switch transfers the load to the standby feed by itself when voltage disappears on the main one.
Is the TransferPacT suitable for backup from a diesel generator?
Yes, the switch is installed between the mains incomer and the generator, and the design does not allow both sources to be closed together. For backup without staff involvement the automatic version is taken.
How does a mechanical ATS differ from a static switch?
A mechanical switch operates with contacts and has a pause for their travel, but works at currents up to 1600 A. STS static switches transfer the load in less than 4 ms and are needed for servers and other sensitive equipment.
Similar products
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.