Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LOW-VOLTAGE EQUIPMENT

БІЗ-21-АО2 — single-channel passive intrinsically safe barrier for 0-20 / 4-20 mA signals

Ex marking II(1)G[ExiaGa]IIC · U0 31.4 V, I0 90 mA · Um 250 V · -40 °C to +70 °C

The БІЗ-21-АО2 is a single-channel passive intrinsically safe barrier for 0-20 mA and 4-20 mA DC current loops. It is installed between field equipment in a hazardous area and a control system located in a safe area. The barrier limits the energy that can reach the hazardous area, so that a spark or heating in the circuit cannot cause ignition. Its maximum output voltage U0 is 31.4 V and its maximum output current I0 is 90 mA. The maximum voltage Um is 250 V. The permissible external capacitance C0 is 0.055 µF and the permissible inductance L0 is 0.7 mH. The passive resistance of the barrier is between 450 and 550 Ω, and the fuse current is 50 mA. The unit carries the explosion-protection marking II(1)G[ExiaGa]IIC. Its 82х23х99 mm housing mounts on a DIN rail. The permitted ambient temperature range is -40 °C to +70 °C. The barrier is used in automation systems at industrial sites with hazardous zones to protect analogue current signals.

Type
single-channel passive intrinsically safe barrier
Protected signals
DC 0-20 mA, 4-20 mA
Ex marking
II(1)G[ExiaGa]IIC
Maximum voltage Um
250 V

Technical specifications

Typesingle-channel passive intrinsically safe barrier
Protected signalsDC 0-20 mA, 4-20 mA
Ex markingII(1)G[ExiaGa]IIC
Maximum voltage Um250 V
Maximum output voltage U031.4 V
Maximum output current I090 mA
Passive barrier resistance450 to 550 Ω
Single-branch resistance330 to 350 Ω
Maximum external capacitance C00.055 µF
Maximum external inductance L00.7 mH
Fuse current50 mA
Leakage current at 24 V5 µA
Leakage current at 4 V1 µA
Leakage current at 0.1 V0.1 µA
MountingDIN rail
Dimensions82х23х99 mm
Ambient temperature-40 °C to +70 °C
Other version in seriesБІЗ-21-АО1: I0 50 mA, 660–700 Ω, L0 1.5 mH

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

The series comes in two versions. Choose the БІЗ-21-АО2 when the loop resistance budget is tight: its passive resistance is 450–550 Ω, with I0 of 90 mA and L0 of 0.7 mH. The БІЗ-21-АО1 has a lower output current I0 of 50 mA and a higher resistance of 660–700 Ω. It also tolerates a higher inductance L0 of 1.5 mH, which matters for long cable runs.

Similar products

Low-voltage equipment

Request a price and lead time

БІЗ-21-АО2 — single-channel passive intrinsically safe barrier for 0-20 / 4-20 mA signals. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.