Ukrainian Components WarehouseA USK project
UKRSKINDUSTRIAL COMPONENTS

LOW-VOLTAGE EQUIPMENT

БІЗ-21-T02 — single-channel passive intrinsic safety barrier for four-wire RTDs

II(1)G[ExiaGa]IIC · U0 13.8 V, I0 116 mA · Um 250 V · -40 to +70 °C

БІЗ-21-T02 is a single-channel passive intrinsic safety barrier for four-wire resistance temperature detectors (RTDs) installed in explosive atmospheres. It is fitted in the safe area between the sensor and the measuring or control equipment. The barrier limits the energy passed into the hazardous circuit, so that neither a spark nor surface heating can ignite the surrounding atmosphere. No separate power supply is required. The protection marking is II(1)G[ExiaGa]IIC. Maximum output voltage U0 is 13.8 V, maximum output current I0 is 116 mA, and the maximum permissible voltage Um is 250 V. The protected circuit may have up to 0.68 µF of capacitance and 1 mH of inductance. Pass-through resistance is 140–162 Ω, with 70–81 Ω per branch. The resistance difference between branches is 0.02 Ω, which matters for accurate four-wire measurement. The 82x23x99 mm housing mounts on a DIN rail and operates from -40 °C to +70 °C. Typical applications are temperature measurement loops in food processing and other plants with hazardous zones.

Number of channels
1
Barrier type
passive
Protected sensors
resistance temperature detectors (four-wire connection)
Protection level
II(1)G[ExiaGa]IIC

Technical specifications

Number of channels1
Barrier typepassive
Protected sensorsresistance temperature detectors (four-wire connection)
Protection levelII(1)G[ExiaGa]IIC
Maximum permissible voltage (Um)250 V
Maximum output voltage (U0)13.8 V
Maximum output current (I0)116 mA
Barrier pass-through resistance140 to 162 Ω
Resistance per branch70 to 81 Ω
Resistance difference between branches0.02 Ω
Maximum permissible capacitance of protected circuit (C0)0.68 µF
Maximum permissible inductance of protected circuit (L0)1 mH
Fuse operating current50 mA
Leakage current, max.at 24 V: not supported; at 4 V: 1 µA; at 0.1 V: 0.1 µA
MountingDIN rail
Overall dimensions82x23x99 mm
Ambient temperature-40 to +70 °C

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

How to choose

Select the version according to the temperature sensor being protected. БІЗ-21-T02 is intended for RTDs connected in a four-wire configuration. For RTDs with a three-wire connection, choose БІЗ-21-T01; for thermocouples, choose БІЗ-21-T03.

Similar products

Low-voltage equipment

Request a price and lead time

БІЗ-21-T02 — single-channel passive intrinsic safety barrier for four-wire RTDs. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.