Bolted connectors and cable lugs for networks up to 1 kV, 1.5–300 mm²

Bolted connectors and cable lugs for cables up to 1 kV for cross-sections of 1.5–300 mm². Conductors of classes 1 and 2 per EN 60228, tested to IEC 61238-1-1. The connectors are designed for heat-shrink joints per DIN SPEC 47640.

Purpose
connection and termination of low-voltage cable conductors
Conductor cross-section
1.5–16 mm² Cu; 4–50 / 25–95 / 25–150+185 SE / 25–185+240 SE / 95–240+300 SE mm²
Conductor classes
1 and 2 per EN 60228, including 120° sector without crimping
Tests
IEC 61238-1-1, class 1 (mech.) and class A (electr.)

Technical specifications

Purposeconnection and termination of low-voltage cable conductors
Conductor cross-section1.5–16 mm² Cu; 4–50 / 25–95 / 25–150+185 SE / 25–185+240 SE / 95–240+300 SE mm²
Conductor classes1 and 2 per EN 60228, including 120° sector without crimping
TestsIEC 61238-1-1, class 1 (mech.) and class A (electr.)
Applicabilityfor heat-shrink joints per DIN SPEC 47640
Connector versionsinspection hole or oil stop; shear bolts or set screws
Connector length30–110 mm
Lugsstandard and NEMA (2 holes), with shear bolts only

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

Cross-sections range from 1.5–16 mm² for copper to 95–240+300 mm² for sector conductors. The enlarged heart-shaped conductor channel makes installation easier, because crushed or protruding conductor ends enter easily and do not catch. Shear bolts have one or two shear points, protrude minimally after installation, and the large hexagonal head does not jam in the tool. Instead of them, set screws with an internal hexagon can be ordered, which allow disassembly. A rotating friction disc at the base of the bolt does not damage the conductor wires and maintains contact pressure, and the transverse grooves of the channel break the oxide film and increase the pull-out force. The connectors come with an inspection hole or with an oil stop that blocks the path of liquid and gas. Lugs are made in standard and NEMA versions with two holes.

How to choose

The deciding parameters here are the cross-section and the conductor class. For copper 1.5–16 mm² there is a separate group, and for larger cross-sections four ranges up to 95–240+300 mm². An oil stop is taken where a barrier for liquid and gas is needed, and an inspection hole where it is important to see the conductor position. For taps without stripping the insulation, see the LV piercing connectors for 1–240 mm² or ISICOMPACT, and for connection to transformer bushings and busbars 2DIREKT up to 4 kA.

Request a price and lead time

Bolted connectors and cable lugs for networks up to 1 kV, 1.5–300 mm². We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What conductor cross-sections are these connectors designed for?

From 1.5–16 mm² for copper to 95–240+300 mm² for sector conductors, including classes 1 and 2 per EN 60228.

What standards are the connectors tested to?

To IEC 61238-1-1, mechanical class 1 and electrical class A. They are designed for heat-shrink joints per DIN SPEC 47640.

How does a connector with an oil stop differ from one with an inspection hole?

The oil stop serves as a barrier for liquid and gas, while the inspection hole makes it possible to see the conductor. Both versions come with shear bolts or with screws.

Are cable lugs available in standard and NEMA versions?

Yes, lugs are made in standard and NEMA versions with two holes, with shear bolts only.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.