БРГ-21 — two-channel galvanic isolation block for analogue signals
Country: Ukraine · Model: БРГ-21
2 channels · input 0–5 mA / 0–20 mA / 4–20 mA / 0–10 V · output 0–5 V / 0–10 V · supply 24 V DC (12–36 V)
The БРГ-21 is a two-channel galvanic isolation block designed to electrically separate analogue current and voltage signal circuits. Each of its two channels operates independently, converting a passive input signal into an active output without cross-influence, which shields measurement circuits from overvoltages, electromagnetic interference and potential shifts. Accepted inputs are 0–5 mA (Rin ≤ 200 Ω), 0–20 mA or 4–20 mA (Rin ≤ 50 Ω) and 0–10 V (Rin ≥ 20 kΩ); the output is 0–5 V or 0–10 V. Conversion accuracy is 0.2 % and isolation voltage is at least 500 V. The unit runs on 24 V DC (12 to 36 V permissible) and draws no more than 50 mA. Its IP20 housing measures 76 × 26 × 115 mm, weighs up to 0.13 kg and mounts on a DIN rail. Typical uses include process control systems, power engineering, metallurgy and the chemical industry, where it matches signals between measurement, control and regulation sections.
- Number of inputs
- 2
- Input signal type
- passive
- Input signal range
- 0–5 mA, Rin ≤ 200 Ω; 0–20 mA, Rin ≤ 50 Ω; 4–20 mA, Rin ≤ 50 Ω; 0–10 V, Rin ≥ 20 kΩ
- Number of outputs
- 2
Technical specifications
| Number of inputs | 2 |
|---|---|
| Input signal type | passive |
| Input signal range | 0–5 mA, Rin ≤ 200 Ω; 0–20 mA, Rin ≤ 50 Ω; 4–20 mA, Rin ≤ 50 Ω; 0–10 V, Rin ≥ 20 kΩ |
| Number of outputs | 2 |
| Output signal type | active |
| Analogue output range | 0–5 V, R ≥ 10 kΩ; 0–10 V, R ≥ 20 kΩ |
| Accuracy | 0.2 % |
| Galvanic isolation voltage | ≥ 500 V |
| Supply voltage | 24 V DC (12 V to 36 V) |
| Current consumption, max | 50 mA |
| Ingress protection | IP20 |
| Mounting | 35 mm DIN rail (EN50022) |
| Dimensions (H×W×D) | 76 mm × 26 mm × 115 mm |
| Weight, max | 0.13 kg |
Specifications are taken from the manufacturer’s technical documentation. Updated .
Description
How to choose
Choose the БРГ-21 when a current (0–5, 0–20, 4–20 mA) or voltage (0–10 V) signal must be isolated and converted to 0–5 V or 0–10 V; the input and output signal codes are specified when ordering. Where a 4–20 mA loop must be passed through with a 4–20 mA output, consider the БРГ-412 or БРГ-422 models instead.
Similar products
Request a price and lead time
БРГ-21 — two-channel galvanic isolation block for analogue signals. We reply within one business day.
Or email office@usk.ua or call +38 (044) 339-50-20.
REQUEST
Need a price, lead time or replacement?
Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.