VH / I protection boards for EV charging points (Mode 2/3)

VH / I are factory-made line protection boards for electric vehicle charging. The combined 1322P-VH2 and 1322P-VH3 have a 22-module enclosure of 270×500×160 mm and provide a Mode 3 line up to 9.2 kW and a Mode 2 line of 2.3 kW. Protection-only boards come in 12 and 22 modules.

Enclosure capacity
12 or 22 modules (270×500×160 mm)
Main breaker
2P 50 A, curve C, 6 kA
Mode 3 charging line
breaker 2P 40 A C 6 kA + RCD 2P 40 A 30 mA, up to 9.2 kW
Mode 2 line
breaker 2P 10 A + Schuko socket 16 A, 2.3 kW

Technical specifications

Enclosure capacity12 or 22 modules (270×500×160 mm)
Main breaker2P 50 A, curve C, 6 kA
Mode 3 charging linebreaker 2P 40 A C 6 kA + RCD 2P 40 A 30 mA, up to 9.2 kW
Mode 2 linebreaker 2P 10 A + Schuko socket 16 A, 2.3 kW
Surge protectionpermanent and transient

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

The boards are designed according to the Spanish technical instruction ICT-BT-52. In the combined versions the main breaker is 2P 50 A, curve C, 6 kA, and next to it there is protection against permanent and transient overvoltages. The Mode 3 line contains a 2P 40 A breaker, curve C, 6 kA, and a 2P 40 A 30 mA RCD. The Mode 2 line has a 2P 10 A breaker and a Schuko 2P+T 16 A 250 V socket with the same 2P 40 A 30 mA RCD, and in the 1322P-VH3 the socket is rated IP67. Such a board is installed where both powerful charging from a wall-mounted station and a household socket for slow charging are needed.

How to choose

Protection-only boards for a charging point are taken when a socket is not needed. The single-phase 1312P-I15 for 12 modules, 270×250×160 mm, has a 2P 40 A breaker, curve C, 10 kA, a 2P 40 A 30 mA class A RCD, protection against overvoltage above 265 V AC and against transient overvoltage Imax 15 kA, class II. The three-phase 1322P-I47 for 22 modules has a 4P 40 A breaker, 10 kA, a 4P 40 A 30 mA RCD and Imax 20 kA protection, class II, and its power reaches 27.6 kW.

Request a price and lead time

VH / I protection boards for EV charging points (Mode 2/3). We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What is the power of the Mode 3 line in VH / I boards?

Up to 9.2 kW, through a 2P 40 A breaker, curve C, 6 kA, and a 2P 40 A 30 mA RCD.

How do the 1322P-VH2 and 1322P-VH3 differ?

In the 1322P-VH3 the household socket has IP67 protection; the rest of the set is the same.

What power is the Mode 2 line rated for?

2.3 kW, with a 2P 10 A breaker and a Schuko 16 A socket.

Which station does the 1322P-I47 board suit?

A three-phase wall-mounted AC station up to 27.6 kW, with a 4P 40 A breaker, 10 kA.

Where are VH / I boards used?

In private garages and in car parks of residential buildings, offices, hotels and shopping centres.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.