CPA / CCF / CLP-C / CSB-F / CSB-M fixed LV capacitors with protection and switching

Fixed LV capacitors with built-in protection and switching for individual compensation of motors and transformers with constant load. The range includes CPA with a circuit breaker, CCF with a contactor and fuses, CLP-C and CSB-F/CSB-M, with stages up to 120 kvar at 440 V. They are installed near the load and do not need a separate panel with protection devices.

CPA
with circuit breaker; up to 120 kvar at 440 V (CPA-120-440: 100 kvar at 400 V, breaker 250 A, 50 kA)
CCF
with contactor and fuses; up to 100 kvar at 440 V (CCF-100-440: 80 kvar at 400 V, fuses 160 A, 120 kA)
CLP-C
CLZ capacitor with breaker and contactor, IP20 (CLP-C-44/25: 25 kvar, 6 kA)
CSB-F / CSB-M
The manufacturer with fuses / with circuit breaker

Technical specifications

CPAwith circuit breaker; up to 120 kvar at 440 V (CPA-120-440: 100 kvar at 400 V, breaker 250 A, 50 kA)
CCFwith contactor and fuses; up to 100 kvar at 440 V (CCF-100-440: 80 kvar at 400 V, fuses 160 A, 120 kA)
CLP-CCLZ capacitor with breaker and contactor, IP20 (CLP-C-44/25: 25 kvar, 6 kA)
CSB-F / CSB-MThe manufacturer with fuses / with circuit breaker
Voltage400 / 440 V, 50 Hz
Insulation3/15 kV (CCF — 3 kV)
Contactor control230 V
Overload1.3 In
Discharge75 V / 3 min

Specifications are taken from the manufacturer’s technical documentation. Updated .

Description

CPA-120-440 gives 120 kvar at 440 V (100 kvar at 400 V) and is protected by a 250 A breaker with a breaking capacity of 50 kA, cable 95 mm². CCF-100-440 has 100 kvar at 440 V (80 kvar at 400 V), a rated current of 131 A, 160 A fuses rated 120 kA, a 70 mm² cable and 230 V contactor control, and CCF stages are made from 10 to 100 kvar. CLP-C-44/25 is a CLZ capacitor with a breaker and contactor in an IP20 enclosure, 25 kvar at 440 V, 33 A, 6 kA. The insulation is 3/15 kV, the tolerance ±10 %, dielectric losses are below 0.2 W/kvar, total losses below 0.5 W/kvar, and discharge is 75 V in 3 min. The rated voltage is 400/440 V, 50 Hz. Overvoltages of 10 % are permissible for 8 h per day, 15 % up to 15 min, 20 % up to 5 min, 30 % up to 1 min, with a continuous overload of 1.3 In. Temperature class D (daily average 45 °C, maximum 55 °C, minimum −25 °C), humidity up to 80 %.

How to choose

First the type of switching is determined. For a constant load CPA with breaker protection is suitable, and if the stage must be switched by a signal, CCF or CLP-C with a contactor is used. The power is selected by the reactive power of the consumer, taking the voltage into account, since at 400 V a capacitor gives less than its 440 V rating, for example 100 kvar instead of 120 kvar for CPA-120-440. For automatic regulation across a workshop it is better to install a computer SMART III controller.

Request a price and lead time

CPA / CCF / CLP-C / CSB-F / CSB-M fixed LV capacitors with protection and switching. We reply within one business day.

* — required fields

Or email office@usk.ua or call +38 (044) 339-50-20.

FAQ

What power does CPA-120-440 have at 400 V?

100 kvar at 400 V and 120 kvar at 440 V. Protection is provided by a 250 A breaker with a breaking capacity of 50 kA.

What is the contactor control voltage of CCF?

230 V. CCF-100-440 is protected by 160 A fuses with a breaking capacity of 120 kA.

What overload do the capacitors withstand?

Continuous overload of 1.3 In. An overvoltage of 30 % is permissible up to 1 min, 20 % up to 5 min, 15 % up to 15 min.

In what temperature range do these capacitors work?

Temperature class D, from −25 °C to 55 °C, daily average 45 °C, humidity up to 80 %.

Similar products

Low-voltage equipment

REQUEST

Need a price, lead time or replacement?

Send us a request and we will confirm the configuration, lead time and delivery terms. We reply by email.

How we use your data

UKRSK, Ukrainian Components Warehouse, is a USK project. This form saves your email, request details, optional name and company, and attached files on the UKRSK server to process your enquiry. Files are not published in the catalogue. The form currently does not perform automated technical matching or send commercial quotations. To enquire about or delete your data, submit a request using this form and include your reference number. Do not attach passwords, payment details or unrelated confidential materials. Technical rate-limit records are stored separately; no advertising trackers are used.

To monitor page performance we collect LCP, INP and CLS measurements, language, screen category and a random measurement ID. These are stored on our hosting for up to 35 days; form contents, email, IP address and full URL are not recorded in this log. No cookies are used; Do Not Track and Global Privacy Control disable measurement.